Vitolight portfolio for facility maintenance and retrofit programs
Vitolight supplies replacement lamps and project lines for offices, retail, hospitality, education, and light industrial sites. The focus is predictable lumen output, stable colour quality, and straightforward maintenance across common bases and lengths.
Vitolight selection guide build your bill of materials by base, lumen class, and CCT
Start broad in Vitolight lamps when assembling a mixed replacement list. Filter by cap type, form factor, colour temperature (2700 K, 3000 K, 4000 K), and lumen class to match existing light levels room by room.
Vitolight fluorescent roadmap for legacy luminaires and staged upgrades
For sites that still run discharge technology due to fixture constraints or phased LED migration, standardize on fluorescent tubes. Verify length and cap (G13), ballast type (electromagnetic with starter versus electronic HF), and photometric targets for corridors, classrooms, and production areas.
Vitolight T8 guidance specification checklist for reliable operation
Use fluorescent tubes T8 where existing luminaires require 26 mm lamps. Before ordering, confirm:
- Length and nominal wattage 600 mm 18 W, 1200 mm 36 W, 1500 mm 58 W equivalents
- Ballast compatibility HF vs EM, starter type, and starting temperature limits
- Lumen package and maintenance L70 expectations for cleaning and relamping cycles
- Colour temperature and CRI policy by zone CRI 80 for offices and back-of-house, CRI 90 for colour-critical displays
- Flicker behaviour with HF ballasts for visual comfort and camera environments
- Environmental ratings ambient range, switching cycles, and mercury handling per local rules
Vitolight engineering criteria for procurement and QA
- Match lumens not watts
Preserve target lux by replacing on lumen output. Document room-by-room targets to keep visual uniformity after maintenance. - Optics and glare
In open luminaires, prefer diffusing optics or opal sleeves to reduce hotspots and UGR. In parabolic louvers, validate beam control and cutoff. - Electrical and thermal limits
Check supply stability, surge exposure, and enclosure temperature. In enclosed fittings, allow thermal headroom to maintain lifetime. - Dimming and controls
Confirm dimmer type and minimum load where applicable. Validate sensor compatibility in offices and classrooms. - Maintenance model
Adopt group relamping for high-access areas to reduce lift time. Keep labelled spares by length, CCT, and CRI for faster storeroom picks.
Vitolight application playbooks
- Offices and education
Neutral white, low glare, occupancy sensor compatibility, and flicker limits for screens. - Retail and hospitality
Warm CCT with higher CRI on merchandise and dining zones; ensure colour consistency across adjacent fixtures. - Light industrial and logistics
Robust tubes with extended temperature range and fast start; verify luminaire IP rating for dusty or damp zones.
Compliance, documentation, and rollout with Vitolight
- Hold CE and relevant EN test summaries, EMC reports, and safety datasheets in the QA pack
- Track batch codes for traceability and warranty handling
- Run acceptance tests lumen checks, CCT spot checks, flicker assessment, and fit tests in representative luminaires
Why source Vitolight from Bank of Lamps
Bank of Lamps is a wholesale distributor with EU-wide delivery from a Latvia warehouse, real-time stock, bulk pricing, and consolidated multi-brand shipments. We help engineering and procurement align lumen targets, CCT policy, ballast compatibility, and replenishment cycles across sites.
If helpful, I can expand this into a tender-ready bill of materials with length and wattage cross-references, zone-based CCT policy, and a quarterly maintenance checklist.