The vimar luminaires range spans recessed and surface panels (600×600, 620×620, 300×1200), linear trunking (open/direct/indirect), compact downlights (Ø68–Ø200 cutouts), wall/ceiling bulkheads, projector floods, and emergency variants (maintained/non-maintained). Output bins typically 800–12 000 lm per module with CRI 80/90 options, CCT 2700–4000–6500 K, UGR<19 office SKUs, and IP20 interiors up to IP65/IP66 for wet zones and façades. Accessories—trim rings, spacers, sealed gaskets, and quick plugs—share the same mounting logic as Vimar boxes and channels.
Office panels and lines use high-transmission diffusers or micro-prismatic optics for UGR control; aisles and high bays add narrow/medium beams with glare shields. Drivers in vimar led luminaires show PF ≥0.95, THD ≤15 %, surge 2 kV L–N / 4 kV L–PE, ripple ≤5–10 % for camera-safe light, and tc marked for void ventilation. LED arrays are LM-80 tested with TM-21 projections; publish L80/B10 targets in the tender so maintenance windows are predictable.
Corridors want 300–500 lx at floor with longitudinal optics; open offices aim for 500 lx on the desk and UGR<19; stair cores prefer IP44 bulkheads with anti-tamper screws; plant rooms run IP65 with higher surge. For vimar indoor lighting, keep one photometry set per SKU (IES/LDT) and lock mounting height, spacing-to-height ratios, and emergency spacing tables into the drawings—acceptance goes quicker when these are fixed early.
Front-of-house lines mix architectural downlights, shallow surface drums, wall grazers, and pendant cylinders with matte white/black, metallics, and wood-tone trims. Dimming is smooth to 1–3 % on DALI; phase options exist for light refurbishments. When you specify vimar decorative lighting, tie finish codes and bezel sizes to room schedules so replenishment never mixes hues or diameters across floors.
Bulkheads and drums cover IP40 indoor and IP65/66 where washdown or weather applies; IK07/08 variants handle schools and back-of-house. Push-fit or screw-fix bezels, captive fasteners, and gasket kits keep ingress ratings after service. In the schedule for vimar ceiling and wall luminaires, list cutout/bolt circle, gland thread, cable Ø, and permitted detergents—cleaning teams won’t guess.
Factory options include DALI-2 DT6/DT8 (tunable white), 1–10 V, push-dim, corridor function, and EM packs with self-test or monitored outputs. For vimar professional lighting fixtures, document minimum dim level, fade times, channel mapping for DT8, and driver inrush (A/µs) versus breaker rows; add 360° braid clamps at gland plates in VFD areas and keep SELV/mains segregated inside canopies.
High-efficacy packages (120–160 lm/W typical) reduce ways and wiring; standby drops below 0.5 W where sensors or controls stay powered. Specify vimar energy efficient lights with CPR/LSZH where routes demand it, and include flicker metrics (PstLM/SVM or percent flicker) when spaces host cameras or sensitive occupants. Declare ambient/ta, tc, and service clearances to protect lifetime.
Supply 220–240 V AC, 50/60 Hz; PF ≥0.95; THD ≤15 %; surge 2/4 kV; ripple ≤5–10 %; CRI 80/90; CCT 2700–6500 K; UGR<19 models where noted. Ingress per IEC 60529; impact per IEC 62262; drivers to IEC/EN 61347-1/-2-13; EMC EN 55015/EN 61000-3-2/-3; control EN 62384. Wiring 0.5…2.5 mm²; strip 8–10 mm; torque per label. Keep 7.5–10 mm breathing around warm gear; record tc at commissioning.
Keystones and frames from Eikon/Arké/Plana match plate geometry; KNX/DALI gateways expose scenes and energy; distribution boards host matching RCBO/SPD stacks. Quick plugs, glands, and labels share the same part numbering, so spares actually fit the fittings you purchased.
We front-load the coordination: one matrix covering optics, outputs, drivers, finishes, IP/IK, cutouts, and inrush versus breaker rows. Quotes come back fast by EAN/MPN with live EU stock, and we reserve lots against your floor sequence so fit-offs aren’t starved. Shipments arrive room- or riser-kitted (luminaire, driver, EM pack where needed, plugs, gaskets, labels) with the IES/LDT set and tc notes inside the carton. Account terms include tracked lead-times, dated price files for cost control, and post-payment for trusted clients. Before anything leaves the warehouse, we sanity-check your schedule—optic codes, dim curves, IP kits, gland threads, and labeling—so installs land cleanly across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.