Register to unlock your exclusive B2B prices and start shopping. Sign up now!

Vimar Electrical Installation

Installers pick Vimar when they want one ecosystem from box to faceplate. The hidden layers—boxes, conduits, ducts, supports, terminals—share consistent geometry and markings, so rooms land straight and maintenance stays painless years later.

vimar installation materials range overview

The backbone covers flush and surface boxes, junction enclosures, mini-trunking, skirting channels, conduits, bends, couplers, glands, fixing clips, and earthing kits. Dimensions track the 55–71 mm module grid with 60 mm screw spacing, so device supports from Eikon, Arké, and Plana align cleanly. Use vimar installation materials to standardize back boxes by depth (40/50/60 mm), knock-out diameters, and screw bosses—your frames will sit flush even on mixed wall types.

vimar mounting systems boxes ducts and supports

Flush boxes for drywall and masonry, metal supports for heavy-duty zones, and low-profile surface pattresses form the core. Ducting and installation channels include single/dual/tri-compartment options with radius corners that respect data-cable bend limits. Crews choose vimar mounting systems with leveling tabs, depth shims, and multi-gang bars (71/71/71 mm pitch) so three-gang scenes stay perfectly aligned over tile joints.

vimar installation accessories gaskets adapters and barriers

Gasket kits push ingress to IP44 for splash areas; separation barriers keep SELV apart from mains; adapter rings rescue oversize cutouts; label windows and engraved tabs keep room IDs consistent. Snap-on spacers (2–10 mm) correct proud plaster, while repair collars tame chipped drywall edges. Stock vimar installation accessories by room type—guest bath, corridor, BOH—so site packs drop onto drawings without ad-hoc buys.

vimar electrical installation design practices and standards

Keep a single coordination sheet listing conductor ranges, torque, strip lengths, and segregation. For acceptance, reference EN 50085 (trunking/channels), IEC 61386 (conduits), EN 60670-1 (boxes), IEC 60529 (IP), and EN 60669-1/-2-1 (switch/dimmer interfaces). In panels and boxes, terminate 0.5…4 mm² Cu at 0.4–0.8 Nm and strip 8–12 mm as printed on device labels. Document how vimar electrical installation routes VFD-noisy circuits away from analog and data, with 360° braid clamps at gland plates where required.

vimar conduit systems materials diameters and IP classes

Rigid PVC and LSZH conduits handle office and hospitality; steel and stainless options add impact resistance and EMC where needed. Typical sizes run 16–63 mm with fittings for IP54–IP67. Minimum bending radii: ≥6×OD for power, ≥10×OD for data. Compression or swivel glands keep pull-in smooth on long runs. On risers exposed to sun or cleaning chemicals, the vimar conduit systems portfolio offers UV-stabilized grades and solvent-weld or threaded joints to match the environment.

vimar wiring components terminals connectors and links

Push-in and screw terminals, insulated ferrules, WAGO-style connectors, earth bridges, and bus links ship with clear gauge icons and color codes. Test points sit where you can actually reach them—handy during commissioning. Where luminaires, sensors, and blinds share back boxes, vimar wiring components maintain bend radius and provide clip points for strain relief, reducing flicker calls caused by loose connections.

vimar installation hardware fixings anchors and supports

You get wall consoles, drop rods, cantilever arms, concrete anchors with ETA ratings, and screw sets that match box plastics. Use toothed washers or serrated nuts to keep bonding metal-to-metal on painted parts. Fire routes can be built with stainless fasteners; declare E30/E60/E90 where specified and record expansion joints. Site teams lean on vimar installation hardware because the screw lengths, thread types, and plugs are consistent across kits—no rummaging mid-shift.

Assortment and series map for procurement

• Boxes and supports: flush boxes 1–4 gang in 40/50/60 mm depths; metal and reinforced plastic supports; multi-gang bars with 71 mm pitch.
• Ducts and channels: EN 50085 trunking, skirting/dado profiles, internal/external bends, tees, reducers, clip-in device plates, lids with snap or screw retainers.
• Conduits and fittings: PVC/LSZH/steel, couplings, elbows, inspection tees, IP54–IP67 glands, clips in 16–63 mm.
• Junction and pull boxes: IP20/IP44 lids, membrane or threaded entries, terminal strips pre-mounted on request.
• Accessories: spacers, barriers, gaskets, adapter rings, repair plates, label windows.
• Hardware: anchors, screws, serrated washers, earth tails, trapeze kits for tray or channel transitions.

Technical specifications and checks that matter

• Temperature and glow-wire: 650 °C fronts, up to 850 °C supports per IEC 60695-2-11; storage −25…+60 °C, operation −5…+45 °C typical.
• Impact: IK05–IK07 depending on frame/support material.
• Ingress: IP20 rooms by default; IP44 with gasketed covers and vertical mounting.
• Conduits: classifications per IEC 61386 for compression, impact, bendability, and temperature.
• Trunking: load and flammability per EN 50085; maintain internal dividers for power/data segregation.
• Identification: laser-etched part codes and flow arrows on channels to keep install orientation aligned with test data.

Applications and compatibility notes

Hotels and offices benefit from multi-compartment channels and gasketed sets in wet areas. Education and healthcare lean on LSZH plastics and antibacterial face options. Industrial corridors use steel conduits and reinforced boxes. All parts align with Vimar device platforms—Eikon, Arké, Plana—so visible trims snap onto the same supports you installed during rough-in.

Selection criteria for B2B buyers

  1. Fix route type and fill factor, then pick box depth, channel compartments, and conduit size.
  2. Choose material/finish by environment: LSZH for escape routes, HDG/steel for impact or EMC, UV-stable where sun hits.
  3. Lock segregation rules and labeling early—circuit group, destination, and test points—and mirror them across floors.
  4. Publish torque, strip lengths, and earthing bonds in the method statement; repeatability saves rework.
  5. Bundle room kits by function: box/support, barrier, gasket, plate, hardware, labels. Faster installs, cleaner QA.

Advantages of working with Bankoflamps

Your build windows drive procurement. Expect job-specific pricing, near-hour quotes by EAN/MPN, and live EU stock before crews are booked. The portal shows lead times, shipment tracking, and downloadable price lists with validity windows you can plan around. Trusted clients can use post-payment up to 30 days. We consolidate partials so boxes, conduits, ducts, channels, supports, terminals, and fasteners arrive route-bundled by level. Your account manager cross-checks spans, materials, IP classes, segregation rules, torque notes, and labeling against drawings—keeping deliveries site-ready across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.