Register to unlock your exclusive B2B prices and start shopping. Sign up now!

Vimar Frames for switches and sockets

vimar frames for switches and sockets dimensions and materials

The vimar frames for switches and sockets portfolio runs single to five-gang with a constant outer line, 60 mm device screw spacing, 71 mm multi-gang pitch, and Ø68 mm drywall cutouts. Bodies come in PC/ABS (standard and halogen-free), anodized aluminum, steel, and tempered glass; UV-stable options resist yellowing near windows. Glow-wire figures (typically 650–850 °C) and IK data are published per finish, so you can match front plates to usage class.

vimar decorative frames finishes and rooms

Matte white/black, warm neutrals, metallics, and glass trims cover reception areas, guest rooms, and meeting spaces; antibacterial surfaces are available for clinics and education. When specifying vimar decorative frames, tie each finish to a room list and engraving policy—engraved legends or insert windows—so day-two replacements don’t mix shades or fonts across a floor.

vimar cover plates apertures, IP options, and labeling

Blank fronts, inscription windows, and gasketed variants support dry rooms or splash zones. Apertures accept power, USB, RJ45/TV/SAT, and indicator modules on the same grid; low-profile options avoid curtain snag at bedside plates. Stock vimar cover plates by aperture type, IP set (IP20 standard, IP44 with gaskets and correct orientation), and color code to keep service kits predictable.

vimar mounting frames supports, claws, and fixings

Steel or reinforced plastic supports provide rigid seating for inserts, with claw or screw mounting for masonry and drywall. Depth shims (2–10 mm) correct proud plaster; separation barriers maintain SELV/mains clearances inside the box. Crews rely on vimar mounting frames because terminals remain accessible for test probes after fit-off and the screw torque/strip rules are identical across the platform.

vimar switch socket frames multi-gang alignment and mixed modules

Scene plates, sockets, data, and blind controls can share a single multi-gang line without breaking the 71/71/71 mm rhythm. Corner radii and edge profiles match installation channels for clean transitions at skirting height. Use vimar switch socket frames when you need long, level runs over tiled or imperfect walls while keeping bending radius for Cat-rated cabling behind the plate.

vimar design series frames mapping to Eikon Arké Plana

Front trims coordinate with Eikon (glass/metal premium), Arké (architectural polymers/metals), and Plana (workhorse series). Insert families are cross-compatible via the common support, so a finish change later doesn’t force box rework. Designers select vimar design series frames early to lock visual language while keeping the ability to swap mechanisms during fit-out.

vimar electrical accessories spacers, gaskets, adapters, and repair parts

Room-ready kits include spacer rings, IP44 gasket sets, repair collars for oversize cutouts, and adapter plates that keep focal height and bezel gaps consistent—useful on refurb floors. Alignment jigs and label windows ship in the same sachets. Bundle vimar electrical accessories with each frame choice so installers land the same torque, strip length (8–10 mm), and label style from level to level.

Technical specifications and standards that matter

Geometry: 60 mm device screws; Ø68 mm drywall cutout; 71 mm multi-gang pitch. Ingress: IP20 standard rooms; IP44 with gasketed sets (confirm mounting orientation). Impact: IK classes per finish. Fire: glow-wire 650–850 °C per IEC 60695-2-11. Materials: PC/ABS, metals, glass; LSZH variants where required (IEC 60754/61034). Compliance touchpoints: EN 60669-1 (mechanisms), EN 60670-1 (boxes/enclosures), IEC 60529 (IP). Terminations follow the insert family, typically 0.5…2.5 mm² Cu at 0.4–0.8 Nm.

Applications and compatibility

Hotels and offices: single aesthetic across public and BOH, with inscription windows for asset codes. Education/healthcare: antibacterial surfaces and higher IK fronts; gasketed sets in cleaning zones. Residential towers and hospitality: mixed power/data/USB on one grid with consistent bezel lines. All trims sit on the same supports used by Vimar switches and sockets, so spares don’t disturb alignment.

Selection criteria for B2B buyers

  1. Fix finish set per area (public/guest/BOH) and lock color codes early.
  2. Choose gang plan and pitch; reserve space for future modules on multi-gang runs.
  3. Define IP/IK where splash or impact applies; add gasket kits and guards as needed.
  4. Set labeling strategy (engraved vs window) and font/size rules to keep plates readable.
  5. Publish torque/strip lengths and SELV barriers in the method statement so every room lands the same QC result.

Bankoflamps supply approach for frame packages

Bankoflamps prices by project, returns quotes quickly using EAN/MPN, and shows live EU stock before rooms are released. Through the client portal you’ll see current lead times, shipment tracking, and downloadable price files with defined validity periods. Trusted customers can work with post-payment terms up to 30 days. Orders are consolidated so supports, trims, covers, gaskets, spacers, barriers, and labels arrive kitted by level or riser, and an account manager checks finish codes, gang layouts, IP needs, segregation notes, and torque/strip rules against your documents to keep deliveries ready for immediate install across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.