Technical Information
| Item condition |
New |
| Manufacture name |
MC 125-B NPE LightningController for N to PE 255V |
| Brand |
OBO Bettermann
|
| Categories |
Surge Protection Devices (SPD)
|
| Country of origin* |
HU |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Harmonized System Code |
8536 3030 00
|
| Mounting method |
DIN rail (top hat rail) 35 mm |
| Lightning impulse current (10/350 µs) |
50 kA |
| Voltage protection level |
2.5 kV |
| Follow current extinguishing capability |
0.1 kA |
| Max. continuous voltage AC |
255 V |
| Nominal discharge surge current (8/20) |
50 kA |
| Nominal voltage AC |
230 V |
| Nominal voltage DC |
0 V |
| Category type 1 |
Yes |
| Voltage protection level L-N |
0 kV |
| Max. continuous voltage DC |
0 V |
| Degree of protection (IP) |
IP20 |
| Voltage protection level N-PE |
0 kV |
Packing details
| Packing level 1 |
4012195966456 |
| Packing level 2 |
4012195966463 |
| Packing level 3 |
4012196902637 |
Other Technical data
| With remote signalling contact |
No |
| Construction size |
2 modular spacing |
| Suitable for outdoor use |
No |
| Exhausting |
No |
| Signalling at the device |
None |
| Integrated backup fuse |
No |
| Max. conductor cross section solid (solid, stranded) |
50 mm² |
| Max. conductor cross section flexible (fine-strand) |
0 mm² |
| Voltage protection level (DC+ - DC-) |
0 kV |
| Voltage protection level (DC+/DC- - PE) |
0 kV |
| Specific energy (W/R) |
0 kJ/Ohm |
| System configuration DC |
No |
| System configuration IT |
No |
| System configuration TN |
No |
| System configuration TN-C |
No |
| System configuration TN-S |
No |
| System configuration TT |
No |
| System configuration other |
No |
| System configuration TN-C-S |
No |
Downloads
Description
Lietošanai TN-S un TT sistēmās kā N-PE dzirksteļsprauga, tips 1 (klase B) IEC 61643, pieslēgvietai 0 uz 1 (LPZ) saskaņā ar zibensaizsardzības zonu koncepciju atb. IEC 61312-1 vai DIN VDE 0185-305, 4. daļu, lietošanai kā dzirksteļspraugu starp N un PE.
Atbilst VDE-AR-N 4100
Izlādes jauda kA (10/350 µs)
Komplektā ietilpst uzspraužami vāciņi pieslēgumu marķēšanai
Aizsardzības līmenis <2,5kV
Iekapsulēta, dzirksteles neizvadoša dzirksteļsprauga: var lietot standarta sadalītāju korpusos
Izmantošanas piemērs: Zibens novadītājs atb. VDE-AR-N 4100 lietošanai zonā pirms elektroenerģijas skaitītāja.