Register to unlock your exclusive B2B prices and start shopping. Sign up now!
SAFETY RELAY TIME DELAY 230VAC image 1

SAFETY RELAY TIME DELAY 230VAC

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
183,33 €
This price is valid until 24.12.25
EAN: 3389110862911
MPN: XPSTSW3742P
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name SAFETY RELAY TIME DELAY 230VAC
Brand Schneider Electric
Categories Safety Relays
Country of origin ID
Harmonized System Code 8536 4190 00
Model Basic device
Number of outputs, safety related, undelayed, with contact 0
Type of electric connection Screw connection
Rail mounting possible Yes
Type of safety according to IEC 61496-1 1
Performance level according to EN ISO 13849-1 Level d
SIL according to IEC 61508 2

Packing details

Packing level 1 3389110862911

Other Technical data

Width 45 mm
Height 99 mm
Depth 114 mm
Release-delay 1-31 s
With approval according to UL Yes
With detachable clamps Yes
With start input Yes
With feedback circuit Yes
Number of outputs, safety related, delayed, with contact 3
Number of outputs, safety related, undelayed, semiconductors 0
Number of outputs, safety related, delayed, semiconductors 0
Number of outputs, signalling function, undelayed, with contact 0
Number of outputs, signalling function, delayed, with contact 0
Number of outputs, signalling function, undelayed, semiconductors 0
Number of outputs, signalling function, delayed, semiconductors 2
Rated control supply voltage at AC 50 Hz 230 V
Rated control supply voltage at AC 60 Hz 230 V
Rated control supply voltage at DC 24 V
With muting function No
With approval for BG BIA Yes
Suitable for monitoring of magnetic switches No
Suitable for monitoring of proximity switches No
Suitable for monitoring of emergency-stop circuits No
Suitable for monitoring of optoelectronic protection equipment No
Suitable for monitoring of position switches Yes
Suitable for monitoring of tactile sensors No
Suitable for monitoring of valves No
Stop category according to IEC 60204 Other
Voltage type for actuating AC/DC
Evaluation inputs 1-channel or 1- and 2-channel

Description

This XPSTSW safety module for applications with safety switch-over contact. It meets the requirements of PL c/Category 2 conforming to EN/ISO 13849-1.and SILCL1 conforming to EN/IEC 61508 and EN/IEC 62061. Used in conjunction with XU2S single-beam photo-electric sensors (periodically tested), it establishes a category 2 light curtain conforming to IEC/EN 61496 parts 1 and 2. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.