Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink image 2
variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink image 3
variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink image 4
MD01 thumbnail 1
variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink thumbnail 2
variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink thumbnail 3
variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink thumbnail 4

variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink

In stock: Yes Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
226,66 €
This price is valid until 31.12.25 or while stock lasts
EAN: 3606480071072
MPN: ATV12H075M2
Package: 1
Pallet: 45
Estimate delivery time at our warehouse (approx.): By request

Technical Information

Item condition New
Manufacture name variable speed drive ATV12 - 0.75kW - 1hp - 200..240V - 1ph - with heat sink
Brand Schneider Electric
Categories Frequency converter =< 1 kV
Country of origin ID
Mains voltage 200-240 V
Mains frequency 50/60 Hz
Number of phases input 1
Relative symmetric net voltage tolerance 10 %
Relative symmetric net frequency tolerance 5 %

Packing details

Packing level 1 3606480071072
Packing level 2 3606480071072

Other Technical data

Width 72 mm
Height 143 mm
Depth 131.2 mm
With control element Yes
Number of digital inputs 4
Number of digital outputs 1
Number of analogue inputs 1
Number of analogue outputs 1
Supporting protocol for LON No
Number of HW-interfaces industrial Ethernet 0
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 1
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 0
Number of HW-interfaces parallel 0
Number of HW-interfaces other 8
With optical interface No
Supporting protocol for TCP/IP No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus Yes
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for other bus systems No
Degree of protection (IP) IP20
With PC connection Yes
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
4-quadrant operation possible No
Number of interfaces PROFINET 0
Type of converter U converter
Number of phases output 3
Integrated breaking resistance No
Application in industrial area permitted Yes
Application in domestic- and commercial area permitted Yes
Max. output frequency 400 Hz
Max. output at linear load at rated output voltage 0.75 kW
Max. output at quadratic load at rated output voltage 0.75 kW
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Max. output voltage 230 V
Nominal output current I2N 4.2 A
Supporting protocol for BACnet No

Downloads

Description

This component is designed to measure and regulate the movement of fluid within a closed-loop system. It serves as a control point, ensuring that flow rates remain consistent according to predetermined specifications. **Electrical Specifications** Operates using low voltage input with standard wiring configuration for industrial applications. Utilizes sensor data to adjust output dynamically—feedback loop integrated into onboard circuitry for faster response times. **Material Compatibility** Metal housing treated for corrosion resistance—suitable for workflows involving water or non-corrosive oils. Seals and connectors rated for moderate pressure environments; not intended for high-temperature operations above 80°C. - Voltage range: 24V–48V DC only, does not support AC operation. - Can handle pressures up to 6 bar but should not exceed manufacturer limits noted in the datasheet. - Sensor connector type: proprietary pin design, requires adapter in some setups. - Maximum operational temperature is limited by internal components' thresholds — avoid continuous use near this limit (approx. 75–80°C). - Limited chemical resistance; unsuitable for strong acids or solvents often used in specialized systems.