Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact image 2
Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact image 3
Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact image 4
MD01 thumbnail 1
Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact thumbnail 2
Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact thumbnail 3
Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact thumbnail 4

Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact

In stock: Yes Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
492,77 €
This price is valid until 31.12.25 or while stock lasts
EAN: 3606480966774
MPN: ATV320U30N4C
Package: 1
Pallet: 12
Estimate delivery time at our warehouse (approx.): By request

Technical Information

Item condition New
Manufacture name Variable speed drive, Altivar Machine ATV320, 3 kW, 380...500 V, 3 phases, compact
Brand Schneider Electric
Categories Frequency converter =< 1 kV
Country of origin ID
Mains voltage 380-500 V
Mains frequency 50/60 Hz
Number of phases input 3
Relative symmetric net voltage tolerance 10 %
Relative symmetric net frequency tolerance 5 %

Packing details

Packing level 1 3606480966774
Packing level 2 3606480966774

Other Technical data

Width 140 mm
Height 184 mm
Depth 158 mm
With control element Yes
Number of digital inputs 6
Number of digital outputs 1
Number of analogue inputs 3
Number of analogue outputs 1
Supporting protocol for LON No
Number of HW-interfaces industrial Ethernet 1
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 1
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 0
Number of HW-interfaces parallel 0
Number of HW-interfaces other 1
With optical interface No
Supporting protocol for TCP/IP No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS Yes
Supporting protocol for CAN Yes
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus Yes
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET No
Supporting protocol for other bus systems Yes
Degree of protection (IP) IP20
With PC connection Yes
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
4-quadrant operation possible Yes
Number of interfaces PROFINET 0
Type of converter U converter
Number of phases output 3
Integrated breaking resistance No
Application in industrial area permitted Yes
Application in domestic- and commercial area permitted No
Max. output frequency 599 Hz
Max. output at linear load at rated output voltage 3 kW
Max. output at quadratic load at rated output voltage 3 kW
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP Yes
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Max. output voltage 500 V
Nominal output current I2N 7.1 A
Supporting protocol for BACnet No
Degree of protection (NEMA) 1

Downloads

Description

This component serves as a current transformer within an electrical measurement system, designed to monitor and step down high currents from a primary circuit into manageable levels for secondary devices. It facilitates accurate metering, control, and protection applications by translating large current values into proportional signals that can be read by downstream equipment. ### Electrical Characteristics The unit operates under high-current conditions typical of industrial or utility-scale power distribution systems. It ensures low impedance in the primary circuit for minimal disruption while offering stable accuracy under standard load requirements. ### Installation Parameters Physical dimensions, mounting points, and lead connections are optimized for integration into panel settings or switchgear assemblies. Designed to comply with IEC safety standards governing current transformers installed in electrical networks. - Maximum rated primary current must not exceed specified limits during operation. - Secondary output requires proper calibration with connected meters or relays. - Performance may degrade if environmental temperatures exceed manufacturer specifications. - Conductors should match specified gauge size to ensure minimal loss over connections.