| Item condition | New |
| Manufacture name | Variable speed drive, Altivar Machine ATV320, 0.75 kW, 380...500 V, 3 phases, compact |
| Brand | Schneider Electric |
| Categories |
Frequency Converters ≤ 1 kV
|
| Country of origin* | ID |
| * The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager. | |
| ETIM | EC001857 |
| Mains voltage | 380-500 V |
| Mains frequency | 50/60 Hz |
| Number of phases input | 3 |
| Relative symmetric net voltage tolerance | 10 % |
| Relative symmetric net frequency tolerance | 5 % |
| Packing level 1 | 3606480966736 |
| Packing level 2 | 3606480966736 |
| Width | 105 mm |
| Height | 142 mm |
| Depth | 158 mm |
| With control element | Yes |
| Number of digital inputs | 6 |
| Number of digital outputs | 1 |
| Number of analogue inputs | 3 |
| Number of analogue outputs | 1 |
| Supporting protocol for LON | No |
| Number of HW-interfaces industrial Ethernet | 1 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 1 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces USB | 0 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | Yes |
| Supporting protocol for CAN | Yes |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | Yes |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | Yes |
| Degree of protection (IP) | IP20 |
| With PC connection | Yes |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| 4-quadrant operation possible | Yes |
| Number of interfaces PROFINET | 0 |
| Type of converter | U converter |
| Number of phases output | 3 |
| Integrated breaking resistance | No |
| Application in industrial area permitted | Yes |
| Application in domestic- and commercial area permitted | No |
| Max. output frequency | 599 Hz |
| Max. output at linear load at rated output voltage | 0.75 kW |
| Max. output at quadratic load at rated output voltage | 0.75 kW |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | Yes |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | Yes |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Max. output voltage | 500 V |
| Nominal output current I2N | 2.3 A |
| Supporting protocol for BACnet | No |
| Degree of protection (NEMA) | 1 |
This component functions as an optical sensor module, designed to accurately measure light intensity or detect variations in illumination levels. Often integrated into automated systems, it translates detected optical inputs into electrical signals for processing by a larger control architecture. ### Electrical Specifications Operates within a low voltage range, typically 3.0V–5.5V DC—compatible with standard circuits powered by microcontrollers or logic units. Average current draw does not exceed 25 mA during operation under typical conditions. Outputs digital signals proportional to the detected light intensity via its interface terminal. ### Optical Parameters Operational wavelength sensitivity is centered around visible and near-infrared spectrum (400 nm–700 nm). Reacts efficiently to changes in incident light within milliseconds—suitable for dynamic applications such as brightness adjustment or object detection in variable lighting environments. **Technical Notes / Limitations:** - Does not include internal amplification; may require external circuitry depending on the application requirements. - Maximum operating temperature: 85°C; performance degrades above this threshold due to material limits. - Input angles over ±20° can cause reduced accuracy in readings due to focusing constraints of the sensor lens arrangement. - Not protected against moisture ingress; confirm enclosure rating if used in humid or wet settings.