Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet image 2
variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet image 3
variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet image 4
MD01 thumbnail 1
variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet thumbnail 2
variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet thumbnail 3
variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet thumbnail 4

variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet

In stock: No Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
4 139,82 €
This price is valid until 31.12.25
EAN: 3606480967108
MPN: ATV340D37N4E
Package: 1
Estimate delivery time at our warehouse (approx.): By request

Technical Information

Item condition New
Manufacture name variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet
Brand Schneider Electric
Categories Frequency converter =< 1 kV
Country of origin IN
Mains voltage 380-480 V
Mains frequency 50/60 Hz
Number of phases input 3
Relative symmetric net voltage tolerance 10 %
Relative symmetric net frequency tolerance 5 %

Packing details

Packing level 1 3606480967108

Other Technical data

Width 213 mm
Height 660 mm
Depth 262 mm
With control element No
Number of digital inputs 8
Number of digital outputs 1
Number of analogue inputs 3
Number of analogue outputs 2
Supporting protocol for LON No
Number of HW-interfaces industrial Ethernet 2
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 1
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 0
Number of HW-interfaces parallel 0
Number of HW-interfaces other 1
With optical interface No
Supporting protocol for TCP/IP Yes
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus Yes
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for other bus systems No
Degree of protection (IP) IP20
With PC connection Yes
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
4-quadrant operation possible Yes
Number of interfaces PROFINET 0
Type of converter U converter
Number of phases output 3
Integrated breaking resistance No
Application in industrial area permitted Yes
Application in domestic- and commercial area permitted No
Max. output frequency 500 Hz
Max. output at linear load at rated output voltage 45 kW
Max. output at quadratic load at rated output voltage 45 kW
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP Yes
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Max. output voltage 480 V
Nominal output current I2N 79.8 A
Supporting protocol for BACnet No
Degree of protection (NEMA) 1

Downloads

Description

This component functions as a control interface within an electrical system, responsible for managing and transmitting input signals to downstream elements. Designed to ensure accurate signal relay, it performs its core function reliably without significant external dependencies. **Electrical Specifications** Rated voltage: Defined parameters based on the application range. Connection terminals designed for secure attachment, minimal resistance loss across contact points. Adheres to standard volt-ampere requirements applicable in industrial settings. **Mechanical Details** Compact housing with dedicated mounting alignment—dimensions optimized for constrained installation environments. Material composition tested for durability under operating conditions; resistant to wear from frequent use cycles. - Suitable only for indoor installations; not rated for high-moisture environments. - Maximum operating temperature: Must not exceed specified thresholds—check accompanying datasheet. - Specific compatibility restrictions apply with certain types of connectors. - Regular maintenance advised after prolonged operational periods.