| Item condition | New |
| Manufacture name | Variable frequency drive DG1-34061FB-C21C 30kW 61A 400V 3-phase IP21 |
| Brand | EATON |
| Categories |
Frequency converter =< 1 kV
|
| Country of origin | CN |
| Mains voltage | 380-500 V |
| Mains frequency | 50/60 Hz |
| Number of phases input | 3 |
| Relative symmetric net voltage tolerance | 10 % |
| Relative symmetric net frequency tolerance | 10 % |
| Packing level 1 | 4015081710904 |
| Width | 237.7 mm |
| Height | 630 mm |
| Depth | 294 mm |
| With control element | Yes |
| Number of digital inputs | 8 |
| Number of digital outputs | 1 |
| Number of analogue inputs | 2 |
| Number of analogue outputs | 2 |
| Supporting protocol for LON | No |
| Number of HW-interfaces industrial Ethernet | 1 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 1 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces USB | 0 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | Yes |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | Yes |
| Supporting protocol for CAN | Yes |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | Yes |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | Yes |
| Degree of protection (IP) | IP21 |
| With PC connection | Yes |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| 4-quadrant operation possible | Yes |
| Number of interfaces PROFINET | 0 |
| Type of converter | U converter |
| Number of phases output | 3 |
| Integrated breaking resistance | Yes |
| Application in industrial area permitted | Yes |
| Application in domestic- and commercial area permitted | Yes |
| Max. output frequency | 400 Hz |
| Max. output at linear load at rated output voltage | 30 kW |
| Max. output at quadratic load at rated output voltage | 37 kW |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | Yes |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | Yes |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Max. output voltage | 500 V |
| Nominal output current I2N | 61 A |
| Supporting protocol for BACnet | Yes |
| Degree of protection (NEMA) | 1 |
Variable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 61 A, Note: Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 72 A, Note: Overload cycle for 60 s every 600 s , Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 30 kW, 110 % Overload: P = 37 kW, 150 % Overload: IM = 55.2 A, 110 % Overload: IM = 68 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 37 kW, 110 % Overload: P = 45 kW, 150 % Overload: IM = 54 A, 110 % Overload: IM = 65 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 40 HP, 110 % Overload: P = 50 HP , Assigned motor rating 150 % Overload: IM = 52 A, 110 % Overload: IM = 65 A, Degree of Protection: IP21/NEMA1, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, Brake chopper, DC link choke, Frame size: FS4, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5