Register to unlock your exclusive B2B prices and start shopping. Sign up now!
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 1
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 2
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 3
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 4
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 5
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 6
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 7
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 8
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 9
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 10
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 11
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 12
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 13
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 14
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 15
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 16
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 17
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O image 18
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 1
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 2
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 3
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 4
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 5
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 6
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 7
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 8
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 9
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 10
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 11
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 12
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 13
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 14
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 15
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 16
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 17
NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O thumbnail 18

NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O

Order only
Price (excl. VAT):
72,11 €
This price is valid until 31.12.25
EAN: 4015082596514
MPN: 259651
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name NZM2/3-XUHIV20208-240AC Undervoltage release, 208-240VAC, +2early N/O
Brand EATON
Categories Trip & Release Units
Country of origin* RO
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8538 9099 00
Type of electric connection Screw connection
Rated control supply voltage at AC 50 Hz 208-240 V
Rated control supply voltage at AC 60 Hz 208-240 V
Rated control supply voltage at DC 0 V
Voltage type for actuating AC

Packing details

Packing level 1 4015082596514

Other Technical data

Delayed No
Suitable for off-load switch Yes
Suitable for overload relay No
Suitable for motor safety switch No
Suitable for power circuit breaker No
Number of contacts as normally closed contact 0
Number of contacts as normally open contact 2
Number of contacts as change-over contact 0

Description

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: for interlocking and load-shedding circuits, as well as for early-make of the undervoltage release in main-switch applications. For use with Emergency-Stop devices in conjunction with emergency-stop button. when the shunt release is energized, accidental contact with the main contacts of the switch during attempts to switch on is safely prevented . Early make of auxiliary contacts on switching on and off (manual operation): approx. 20ms. Cannot be used in conjunction with NZM...-XR.. remote operator. Undervoltage releases cannot be installed simultaneously with NZM..-XHIV.. early-make auxiliary contact or NZM..-XA.. shunt release. Can be used for: NZM2(-4), N(N/O)2(-4), NZM3(-4), N(N/O)3(-4)