Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Type1+2+3 combined arrester DEHNshield ZP 2 SG for TN-S systems image 1
Type1+2+3 combined arrester DEHNshield ZP 2 SG for TN-S systems image 2
Type1+2+3 combined arrester DEHNshield ZP 2 SG for TN-S systems image 3
Type1+2+3 combined arrester DEHNshield ZP 2 SG for TN-S systems thumbnail 1
Type1+2+3 combined arrester DEHNshield ZP 2 SG for TN-S systems thumbnail 2
Type1+2+3 combined arrester DEHNshield ZP 2 SG for TN-S systems thumbnail 3

Type1+2+3 combined arrester DEHNshield ZP 2 SG for TN-S systems

Order only
Price (excl. VAT):
565,68 €
This price is valid until 24.12.25
EAN: 4013364424715
MPN: 909640
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name Type1+2+3 combined arrester DEHNshield ZP 2 SG for TN-S systems
Brand Dehn
Categories Surge Protection Devices (SPD)
Country of origin* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8536 3090 00
Lightning impulse current (10/350 µs) 50 kA
Max. continuous voltage AC 255 V
Nominal voltage AC 230 V
Test class Type 1 and 2 and 3
Degree of protection (IP) IP30
Voltage protection level N-PE 1.5 kV
Voltage protection level L-PE 1.5 kV

Packing details

Packing level 1 4013364424715, 4013364424715

Other Technical data

Mounting method Busbar
Number of poles 4
Follow current extinguishing capability 25 kA
Signalling at the device Optic
Max. conductor cross section solid (solid, stranded) 25 mm²
Specific energy (W/R) 39.06 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment Yes
System configuration TN-S Yes
System configuration TT No
Max. overcurrent protection device, parallel connection (fuse) 160 A
Max. overcurrent protection device, series connection (fuse) 160 A
Voltage switching spark gap technology Yes
Overcurrent protected voltage tapping Yes

Downloads

Description

Tested type 1 + type 2 + type 3 combined arrester according to IEC 61643-11 for TN-S systems (4+0 configuration) including overcurrent-protected 230 V power supply (N and L) including spare fuse for the compartment for additional applications / termination point meter mounting board according to VDE-AR-N 4100; can be installed completely without tools thanks to click + power connection method for 40 mm busbar systems and push-in earthing terminal; for use in the main power supply system according to IEC 60634-4-44 clause 443 of buildings with an external lightning protection system (class of LPS III/IV). A suitable cover clip according to DIN VDE 0603-1 for every standard meter panel and 2 x socket and 2 x plug (without connecting cables) for wiring the intelligent measuring system according to VDE-AR 4100 are included in delivery.