Register to unlock your exclusive B2B prices and start shopping. Sign up now!
FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester image 1
FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester image 2
FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester image 3
FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester image 4
FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester thumbnail 1
FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester thumbnail 2
FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester thumbnail 3
FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester thumbnail 4

FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
799,68 € per pcs
This price is valid until 24.12.25
EAN: 4055626003825
MPN: 2905871
Box: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name FLT-SEC-H-T1-3C-264/25-FM - Type 1+2 combined lightning current and surge arrester
Brand Phoenix Contact
Categories Surge Protection Devices (SPD)
Country of origin DE
Harmonized System Code 8536 3030 00
Mounting method Other
Lightning impulse current (10/350 µs) 25 kA
Voltage protection level 1.5 kV
Follow current extinguishing capability 50 kA
Max. continuous voltage AC 264 V
Nominal discharge surge current (8/20) 25 kA
Nominal voltage AC 240 V
Nominal voltage DC 0 V
Category type 1 Yes
Voltage protection level L-N 0 kV
Max. continuous voltage DC 0 V
Voltage protection level N-PE 0 kV

Packing details

Packing level 1 4055626003825, 4055626003825

Other Technical data

With remote signalling contact Yes
Number of conductors (without earthing) 0
Construction size Other
Exhausting No
Signalling at the device Optic
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 35 mm²
Voltage protection level (DC+ - DC-) 0 kV
Voltage protection level (DC+/DC- - PE) 0 kV
Specific energy (W/R) 0 kJ/Ohm
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C Yes
System configuration TN-S No
System configuration TT No
System configuration other No
System configuration TN-C-S No

Description

Plug-in lightning current arrester, in accordance with Type 1/Class I, with integrated surge-proof fuse, for 3-phase power supply networks with combined PE and N installed in one conductor (L1, L2, L3, PEN).