Register to unlock your exclusive B2B prices and start shopping. Sign up now!

TRILUX Floor lamps

trilux floor lamps for offices and hospitality zones

Trilux uses the same optical discipline from its workplace luminaires in freestanding bodies that sit neatly beside desks, sofas, or consultation tables. Output spans roughly 3,000–12,000 lm with balanced up and down light for uniform ceilings and readable desktops. Expect UGR ≤ 19 with micro-prismatic or lens optics, CRI 80 or 90, and standard CCTs at 3000 K and 4000 K to match existing schemes. Drivers run on 220–240 V AC, PF ≥ 0.90, THD typically below 15%, standby around 0.5 W. IP20 is the norm for interiors; robust weighted bases and anti-tilt geometry keep units stable on carpet or raised floors. To support layout flexibility, many bases fit under desk legs and offer 3–5 m cords with Schuko plugs. In daily use, installers value that trilux floor lamps ship with sensible dimming curves that do not spike at low levels.

trilux standing lamps range and optical options

Portfolios usually group two families: task-centric heads for single or double desks and decorative heads for lounges. Upward distribution often covers 60–70% to lift general illuminance, while the remaining 30–40% forms a low-glare task component. Lensed variants deliver strong spacing ratios in open plans; micro-prism versions blend more softly in hospitality corners. Tool-less column access helps service the driver and control gear. To maintain wording consistency in specs and drawings, project engineers often tag one line as trilux standing lamps so accessories and spares stay aligned across floors.

trilux led floor lighting technical specifications

For office grade control, DALI-2 drivers with corridor function are common; presence and daylight sensors can be column-mounted or integrated in the head. Flicker is kept low for camera and screen comfort; modern drivers land in the single-digit percent range under nominal load. Efficacy typically runs 110–150 lm/W depending on optic and CCT. Choose CRI 90 where brand areas or healthcare reading zones need truer colour. Thermal paths use extruded aluminium with hidden fins; housings remain touch-safe within IEC 60598 limits at 25 °C ambient. Cabling is tidy: plug-and-play in the base, strain-relieved at entry, and shielded leads for control where needed. When tender notes require a short phrase for cross-reference, teams often write trilux led floor lighting to keep the package unambiguous.

trilux decorative floor luminaires applications and compatibility

In lounges, receptions, and patient waiting areas, the brief is less about 500 lx at the desk and more about atmosphere and modelling. Here, warm 3000 K, CRI 90, and softer beam shaping read best on fabrics and timber. Switch-dim or Casambi-ready drivers simplify retrofit scenes without touching the BMS backbone; DALI versions still integrate cleanly with gateways. Glare rings, diffusers, and fabric shades can be specified to echo pendant families. Designers usually mark these units as trilux decorative floor luminaires in schedules to separate them from task-focused free-standing office lights.

trilux modern standing lights integration with Trilux systems

Linking into building controls is straightforward: DALI-2 for groups, broadcast for agile areas, or wireless nodes where cabling is impractical. Presence-controlled clusters keep daytime consumption down; evening scenes can cap uplight while preserving vertical illuminance for safety. Emergency options include maintained in-head modules or external central-battery feeds routed through the column. When aligning with linear trunking or pendants from the same brand, match CCT, CRI, and lumen-per-metre targets so the visual hierarchy stays intact. Spec sheets often label this family as trilux modern standing lights to indicate office-grade optics and controls.

trilux indoor floor fixtures selection criteria for B2B buyers

Confirm task model versus decorative model first, then lock photometric needs: target desk lx, UGR, and ceiling brightness. Choose CCT and CRI to suit the space; 4000 K CRI 80 covers most back-office areas, while 3000 K CRI 90 suits client zones. Decide the control stack early: switch-dim for small rooms, DALI-2 with sensors for open plans, or BLE commissioning where moves are frequent. Check base geometry against furniture feet, cable management slots, and power-track locations. For maintenance, note driver type, expected lifetime (often L80 50–60k h at 25 °C), and replaceable sensor kits. Procurement teams usually cite trilux indoor floor fixtures in RFQs so warehouse labelling matches drawings.

trilux freestanding led lamps procurement with Bankoflamps

You get project pricing aligned to your programme, near-hour quote turnaround by EAN or MPN, and live EU stock before you commit crews. The portal shows current lead times, shipment tracking, and downloadable price lists with defined validity periods for planning. Trusted customers can use post-payment up to 30 days. We consolidate partials so columns, heads, drivers, sensors, and accessories arrive room-bundled. Your account manager cross-checks lumen packages, optics, control type, plug style, and base footprints against your schedules to keep the unpack-to-install path short across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands. Many clients explicitly request trilux freestanding led lamps on pick lists to make site receipts frictionless.

Applications and compatibility

Open offices: sensor-equipped units maintain uniform horizontal and vertical illuminance with UGR ≤ 19 and smooth fades for low acoustic impact. Reception and hospitality: decorative heads provide softer gradients, good skin-tone rendering, and modest uplight to lift ceilings. Meeting rooms: DALI-2 scene calls or BLE apps shift from presentation to collaborative work without swapping luminaires. Healthcare administration: flicker-controlled drivers and easy-clean surfaces help with visual comfort and hygiene routines. For clarity in hand-over docs, include the phrases trilux floor lamps, trilux standing lamps, trilux led floor lighting, trilux decorative floor luminaires, trilux modern standing lights, trilux indoor floor fixtures, and trilux freestanding led lamps exactly once each in schedules.

Integration with other Trilux products

Match these freestanding units with the brand’s linear pendants, recessed downlights, and wall lights to keep one optical language. Re-use the same CCT bins, CRI, and control profiles so BMS scenes behave predictably. Where desks shift often, wireless control nodes pair well with the floor units while trunking stays on DALI-2.

Product range and series overview

Expect office-grade free-standing luminaires for single and double desks, decorative variants for hospitality, and hybrid heads that add upward illumination to support ceiling brightness in deep plans. Options include presence and daylight sensors, emergency modules, tunable-white in select lines, and finishes in white, black, or aluminium to match furniture systems. Columns and heads are usually serviceable with standard tools; drivers and sensors are modular for quick swap.

Technical specifications and standards

Supply 220–240 V AC, 50/60 Hz. Efficacy 110–150 lm/W, lumen packages around 3–12 klm, CRI 80/90, CCT 3000 K and 4000 K, PF ≥ 0.90, THD ≤ 15%, standby ≈ 0.5 W. UGR ≤ 19 for desk work, IP20, IK rates per model. Controls: switch-dim, DALI-2, or BLE; presence and daylight sensors optional. Lifetime targets commonly L80 50–60k h at 25 °C ambient. Housing aluminium with micro-prism or lens optics; up light 60–70% typical. EMC, safety, and control compliance are met through the brand’s standard luminaire design practice without over-specifying paperwork in the tender.