Register to unlock your exclusive B2B prices and start shopping. Sign up now!

THORGEON LED Lamps GU10 Dimmable

thorgeon gu10 dimmable led lamps optical and electrical performance

Accent circuits need punch without glare. Packages span 350–800 lm at 3.8–7 W, CRI 90 options for retail, and 2700/3000/3500/4000 K held within SDCM ≤3. Beams 10°/15°/24°/36°/60° cover vitrines to corridors. Power factor ≥0.90 with THD <15 %, surge 1–2 kV, and flicker metrics within PstLM/SVM guidance on approved controls. Drivers are enclosed-rated where specified; verify Tc at the cap ring after 60 minutes to protect lifetime on thorgeon gu10 dimmable led lamps.

thorgeon dimmable led spotlights control behaviour and scene repeatability

Trailing-edge dimmers give quiet, smooth low-end (typically 5–10 %); DALI and 0–10 V variants keep scene floors identical across bays. Minimum level, curve type, and warm-restart are documented so scenes clone from room to room. On mixed estates, approved pairings avoid shimmer and acoustic buzz, and centre-beam candela stays stable at low dim on thorgeon dimmable led spotlights.

thorgeon gu10 dimmable bulbs thermal paths and mechanics

Die-cast heat sinks and aluminium cores hold case temperature; keep 100–150 mm free space above trims and avoid insulation contact unless the luminaire allows. Lens options include clear TIR for maximum candela and micro-prism faces for glare control. Front-glass SKUs protect open fittings. Terminals accept 0.5…2.5 mm², strip 8–10 mm; glands M16/M20 maintain enclosure IP when cans are sealed around thorgeon gu10 dimmable bulbs.

thorgeon recessed dimmable lighting spacing optics and UGR planning

At 2.7–3.0 m height, 24° delivers crisp 3:1 accents on merchandise; 36° smooths corridor art without hot spots; 60° softens tables in dining. Use the beam-edge rule for spacing and keep luminance under 1 500 cd/m² at 65° where office glare limits apply. Corridor function with presence/daylight keeps base levels in vacant periods for thorgeon recessed dimmable lighting.

thorgeon adjustable gu10 led bulbs aiming hardware and retention

Gimbal and tilt rings provide ±30–40° with firm detents; serrated washers and thread-lock stop drift on vibrating soffits. Record standoff, tilt, and torque on the drawing so night crews repeat settings. Factor-1 reflectors keep beam feel consistent across finishes, which simplifies refocus tasks using thorgeon adjustable gu10 led bulbs.

thorgeon retrofit dimmable gu10 lights compatibility and inrush notes

Legacy phase controls vary. Specify trailing-edge where policy allows; add a bleed only if site standards permit. Low-inrush driver options keep relay banks stable; warm-restart avoids pop-on at low scenes. For maintained emergency circuits, declare emergency flux (typically 120–300 lm) and confirm inverter start voltage on thorgeon retrofit dimmable gu10 lights.

thorgeon indoor dimmable spot lamps applications and integration

Galleries, boutiques, and reception walls benefit from CRI 90 at 3000–3500 K; offices prefer 36° at 3000/4000 K to lift objects without screen glare; corridors use 24° to reach artwork at height. Frames, collars, and trim depths match common can geometries, and EMC is preserved via 360° shield clamps at gland plates when drivers sit near VFDs—practices crews keep consistent with thorgeon indoor dimmable spot lamps.

Product range and series overview

Outputs 350–800 lm, beams 10°–60°, CRI 80/90, CCT 2700–4000 K; GU10 mains with phase-cut, and DALI/0–10 V variants where central control is present. Enclosed-rated options protect sealed cups; front-glass SKUs for open luminaires.

Technical specifications and standards for engineers

  • Electrical: 220–240 V, PF ≥0.90, THD <15 %, surge 1–2 kV L-L; inrush data available for relay sizing.
  • Optical: SDCM ≤3 colour consistency; centre-beam candela tables per lumen bin for aiming.
  • Thermal: verify Tc at one hour; ambient −20…+40 °C; keep clear air above trims.
  • Compliance: caps per IEC 60061; LED modules EN 62031; safety/performance EN 62560/EN 60598; EMC EN 55015 with immunity EN 61547.

Selecion criteria for B2B buyers

  1. Fix accent ratio and mounting height, then choose beam and centre-beam candela.
  2. Lock CCT/CRI by material palette and space type.
  3. Choose control topology and publish approved dimmers or DALI drivers with minimum level.
  4. Confirm trim clearance, “enclosed-rated” need, and Tc measurements.
  5. Record ferrule size, strip window, torque, gland thread, and surge class in the worksheet.
  6. Room-bundle by lumen bin and beam so aiming charts and audits stay consistent.

Advantages of working with Bankoflamps

We deliver in the sequence crews install and focus. Quotes with EAN/MPN arrive in about an hour, and live EU stock is visible before teams are booked. Your portal shows lead times, shipment tracking, and downloadable price files with validity periods you can plan around. Trusted accounts use post-payment up to 30 days. We consolidate per zone so lamps, trims, collars, glands, and control gear land together, and your account manager cross-checks lumen bins, beams, control method, Tc limits, ferrule sizes, surge class, and torque notes against your drawings—keeping GU10 dimmable packages site-ready across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.