Register to unlock your exclusive B2B prices and start shopping. Sign up now!

Sylvania Starters for lighting

0,84 €
This price is valid until 31.12.26 or while stock lasts
EAN: 0447375923402
MPN: SYL9024495
Package: 1
Estimate delivery time at our warehouse (approx.): By request
0,403 €
This price is valid until 31.03.26
Subtotal: 403,00 € MOQ: 1000
EAN: 5410288244181
MPN: 24418
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks
0,403 €
This price is valid until 31.03.26
Subtotal: 403,00 € MOQ: 1000
EAN: 5410288244198
MPN: 0024419
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks
0,403 €
This price is valid until 31.03.26
Subtotal: 10,07 € MOQ: 25
EAN: 5410288244211
MPN: 24421
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks
2,99 €
This price is valid until 31.03.26
Subtotal: 74,75 € MOQ: 25
EAN: 5410288244716
MPN: 24471
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks
0,403 €
This price is valid until 31.03.26
Subtotal: 10,07 € MOQ: 25
EAN: 5410288244204
MPN: 0024420
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

sylvania starters for lighting applications and scope

Retrofit estates and OEM trays still rely on discrete starting hardware where control gear is split. These units cover glow starters for classic T8/T12 circuits, electronic preheat for low-temperature starts, and HID triggers with defined pulse energy and cable limits. On drawings, engineers mark sylvania starters for lighting when they want predictable strike behaviour, calm EMC, and clean replacement logic across phases. In fluorescent maintenance, a starter is often the fastest way to separate “lamp issue” from “control gear issue.” When a tube refuses to ignite, starts only after several attempts, or behaves differently from fixture to fixture, technicians typically replace the starter first because it’s cheap, quick, and immediately diagnostic. For day-to-day service work where teams need a simple replacement part that keeps older installations operational, practical options like zext starters for lighting are commonly used as a straightforward swap in routine fittings. In budget-driven refurbishments and quick fixes, the goal is often to restore function without changing the fixture or rewiring. In those situations, maintenance teams frequently reach for accessible replacements such as thorgeon starters for lighting, treating the starter as a consumable that can stabilise ignition and reduce repeated start attempts. When the site has mixed fixture generations and incomplete documentation — typical in older buildings, corridors, storage zones and back-of-house areas — compatibility becomes the main priority. Electricians often keep versatile solutions like spectrum starters for lighting on hand as a practical “fits most” option for varied installations. Some environments add mechanical and environmental stress: outdoor housings, temporary power setups, service areas with vibration or frequent access. Here, robust build and reliable behaviour matter more than saving a small amount per unit, so installers often choose utilitarian components such as schwabe starters for lighting when they want fewer surprises under harsher conditions. And for organisations that standardise spares across many locations, the starter becomes a procurement item where consistency is the whole point. In these multi-site maintenance models, teams often default to globally recognised references like philips starters for lighting, ensuring replacement behaviour stays predictable regardless of fixture age or site.

sylvania fluorescent lamp starters types and ratings

Glow types follow IEC 60155 with series capacitor where required; common ratings pair with 18/36/58 W T8 lines on 220–240 V, 50/60 Hz. Preheat time sits ~0.5–1.5 s to protect cathodes, and life is dominated by switch counts and ambient. For enclosed bulkheads or stair cores, pick thermal classes that tolerate warm cavities. Installers choose sylvania fluorescent lamp starters to stabilise ignition on legacy magnetic ballasts without disturbing breaker curves.

sylvania ignitors for lamps HID systems and pulses

HID triggers must match ballast topology and lamp chemistry. Superimposed designs sit at the ballast with 2–5 kV pulses; series designs live near the lampholder and respect strict cable lengths. Pulse repetition and energy are declared so hot-restrike plans are realistic. When documents specify sylvania ignitors for lamps, crews lock the ignitor code to the ballast family to avoid nuisance cycling and premature arc tube ageing.

sylvania lighting control starters coordination with sensors

Presence and daylight logic can slash strike counts if timers and inhibit inputs are wired correctly. Preheat profiles, minimum on-times, and fade-down rules are set upstream so cathodes aren’t pecked by rapid switching. In classrooms and corridors, planners tag sylvania lighting control starters where occupancy, manual override, and emergency testing must coexist without fighting each other.

sylvania cfl and fluorescent starters wiring practice

Two-pin CFL/magnetic T8 circuits keep the starter in series with heaters; four-pin HF circuits do not use external starters at all. Always confirm holder wear and spring force, replace brittle caps, and check PFC capacitor health on magnetic gear. For cold rooms or draughty atria, projects adopt sylvania cfl and fluorescent starters with extended preheat or electronic variants that maintain lamp life under frequent cycling.

sylvania electronic ignitors selection for ballasts

Electronic HID gear benefits from matched triggers with known dv/dt and EMC behaviour. Surge paths are short and earth tails direct; shielding continuity is preserved with 360° clamps at entry plates. Declare cable lengths and isolation class, and keep pulse wiring away from control buses. Procurement teams list sylvania electronic ignitors by wattage range, pulse type, and connector style to keep spares clean.

sylvania lamp starting devices procurement and QA

Acceptance checks include strike count at temperature, pulse compliance, insulation resistance, and correct end-of-life behaviours (starter lockout, HID cycling prevention). Labels with EAN/MPN and batch codes simplify audits; QR tags map assets to drawings. For phased rollouts, maintenance kits group sylvania lamp starting devices with holders, capacitors, and gaskets so night shifts aren’t chasing small parts.

Technical specifications and standards for engineers

  • Fluorescent glow starters: IEC 60155; typical lamp matches 15–65 W T8/T12; preheat ~0.5–1.5 s; voltage 220–240 V.
  • HID starting devices: IEC 60927 for non-glow starters; gear safety IEC/EN 61347; caps per IEC 60061; EMC EN 55015; harmonics EN 61000-3-2.
  • Wiring: terminals 0.5…2.5 mm² per EN 60999; observe ignitor cable-length limits; keep pulse wiring segregated from SELV control.
  • Environment: −25…+50 °C typical; select thermal class for enclosed fittings; surge coordination at feeder and head.

Applications and compatibility

  • Offices and schools: preheat starters with minimum on-time settings to reduce cathode wear under presence control.
  • Social housing and stair cores: thermal-class starters that tolerate warm voids; ensure emergency circuits are upstream of dimming.
  • Warehouses and yards: HID triggers matched to ballast and lamp voltage; confirm hot-restrike feasibility and contactor ratings.
  • Healthcare and labs: low-EMI layouts with short earth paths and shielded entries to protect instrumentation.

Selection criteria for B2B clients

  • Define lamp and ballast family first, then fix starter/ignitor topology and pulse spec.
  • Document end-of-life lamp voltage and gear settings; set group relamp and cycling thresholds.
  • Standardise holder series and connector types; keep one starter class per floor to control van stock.
  • Record torque for gland and terminal closures; log cable lengths for series ignitors.

Advantages of working with Bankoflamps

Project pricing aligns to room and area schedules, and live EU stock is visible before crews are booked. Quotes land in about an hour with EAN/MPN so variants stay fixed. Your portal shows lead times, shipment status, and downloadable price lists with stability windows suitable for phased works. Approved clients can use post-payment up to 30 days. We consolidate partials to cut freight, and an account manager cross-checks ballast pairing, pulse type, cable length limits, IP/IK of enclosures, gasket kits, and strain-relief details against your drawings so cartons arrive site-ready across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.