Register to unlock your exclusive B2B prices and start shopping. Sign up now!

Sylvania LED Tubes

sylvania led tubes for commercial retrofits

Sylvania’s retrofit lines are built to land fast on existing grids and deliver predictable commissioning. Drivers sit calmly on 220–240 V AC, PF ≥0.9, THD ≤15% (model dependent), and binning holds colour in ≤3-step SDCM so phases match. Glass or shatterproof polycarbonate barrels keep rigidity in troffers and trunking. Where estates phase upgrades floor by floor, engineers specify sylvania led tubes to standardise outputs, wiring practice, and accessories without touching pole spacing or reflectors.

sylvania t8 led tubes formats and wiring

G13 caps cover single-ended and double-ended feed options. Mains-ready types replace the old starter with an LED fuse; HF-compatible variants keep the electronic ballast in place; full-conversion kits remove gear entirely and wire direct to line/neutral. Typical sizes 600/1200/1500 mm, 900–3,600 lm, 100–160 lm/W depending on CCT and beam. For open-plan offices and schools, teams deploy sylvania t8 led tubes where legacy troffers must stay but energy and maintenance costs need to come down.

sylvania t5 led tubes photometrics and drivers

Slim G5 bodies serve pelmets, continuous lines, and shallow louvred fittings. Output sits around 1,600–4,500 lm with efficacy commonly 120–165 lm/W. HF-compatible versions respect existing ECGs; direct-wire SKUs publish inrush so MCBs can be sized correctly. Glare control remains a luminaire function—choose prismatic diffusers or micro-baffle optics where EN 12464-1 targets apply. Specifications call for sylvania t5 led tubes in long runs when pitch, cut-out, and gear-tray geometry cannot change mid-programme.

sylvania fluorescent replacement tubes installation and safety

Conversion must respect IEC 62776 (double-capped LED lamps), EN 60598 (luminaires), and wiring clarity inside the gear tray. Label the fitting after rewire, keep earth continuity, and isolate removed ballasts. In magnetic systems, replace the starter with the supplied fuse; in HF systems, use only listed ECG-compatible models. Projects mark sylvania fluorescent replacement tubes on room schedules to keep “kit type” visible to maintenance and avoid mixed wiring in the same bay.

sylvania linear led lamps applications and compatibility

Education and offices target 300–500 lx with calm dimming; retail prefers high-CRI accents on verticals; parking and corridors run standby 10–30% for safe egress. Colour sets 3000/4000/6500 K, CRI 80 standard with CRI 90 options, ripple kept within PstLM/SVM guidance for workspaces. When tender notes reference sylvania linear led lamps, designers lock CCT/CRI per zone and align diffuser type across batches so ceilings read as one surface.

sylvania energy efficient tube lights controls and efficiency

DALI-2 broadcast or addressed control, 1–10 V where legacy dimmers persist, and clean push-dim are all supported when paired with suitable drivers. Daylight-linked set-points and presence logic trim run-hours without visible hunting. Emergency variants (maintained and non-maintained) follow EN 60598-2-22 with addressable test where required. Energy teams choose sylvania energy efficient tube lights to meet kWh targets while keeping wiring topology and breaker curves intact.

sylvania led tube fixtures options for new builds

When new bodies are permitted, trunking and sealed IP65/IP66 battens ship with pre-wired through-feeds, stainless clips, and closed-cell gaskets. Lumen packages span ~2,000–18,000 lm with opal or rack optics; surge protection typically 2–4 kV L-N indoors and up to 6 kV in car parks. Specifiers select sylvania led tube fixtures to keep optics, control gear, and accessories unified from corridor to plant room without mixing vendors.

Technical specifications and standards for engineers

  • Electrical: 220–240 V AC, 50/60 Hz; PF ≥0.9; THD ≤15%; declared inrush for MCB sizing; surge 1–2 kV on lamp-integrated gear.
  • Photometric: 2700/3000/3500/4000/6500 K; CRI 80/90; ≤3 SDCM; typical 100–165 lm/W depending on format.
  • Mechanical: G13 (T8) and G5 (T5) caps to IEC 60061; glass or PC barrels; shatterproof sleeves on request.
  • Environment: −20…+45/50 °C model dependent; IP20 in troffers, higher when housed; keep airflow around converted trays.
  • Compliance: IEC 62776 LED tubes, EN 60598 luminaires, EN 61347 driver safety, EN 61000-3-2 harmonics, EN 55015 emissions, EN 62471 photobiological assessment.

Applications and compatibility notes

  • Offices and classrooms: addressed DALI-2 for scenes/daylight; UGR managed by the luminaire, not the lamp.
  • Retail: CRI 90 and tighter SDCM on wall runs; verify vertical lux.
  • Housing and corridors: standby profiles 10–30%; LED starter fuses documented at the gear tray.
  • Parking and plant: sealed fixtures with higher surge; verify cable entry threads and gland sizes.
    Always record whether a fitting is ECG-compatible or direct-wire to prevent mixed wiring on the same circuit.

Integration with other Sylvania products

Tie retrofits to Sylvania sensors, wall keys, and DALI power supplies so presence, daylight, and emergency tests share one logic chain. Where wet or dusty, pair with Sylvania 3-proof lines; for accent zones, match pendants or spots on the same CCT/CRI to keep colour harmony.

Selection criteria for B2B clients

  • Define wiring path early: ECG-compatible vs direct-wire vs kit conversion.
  • Fix lumen class, CCT/CRI, and spacing against target lux and glare constraints.
  • Confirm inrush and PF on shared phases; align MCB curves floor by floor.
  • Choose sleeve material (glass vs PC) by environment and cleaning chemicals.
  • Document emergency method and test regime; keep spare fuses and labels in the room bundle.

Advantages of working with Bankoflamps

We align B2B pricing to room schedules and show live EU stock before crews are booked. Quotes land in about an hour with EAN/MPN so variants stay fixed. Your portal lists lead times, shipment status, and downloadable price lists with stable validity windows. Approved clients can use post-payment up to 30 days. We consolidate partials to cut freight, and your account manager cross-checks wiring scheme, lumen pack, CCT/CRI, dimming interface, surge level, and accessory kits against your drawings so cartons arrive site-ready across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.