Continuous and stand-alone bodies share drivers, lenses, and accessory threads so crews can repeat details floor to floor without rework. Typical figures: 220–240 V AC, PF ≥0.9, THD ≤15% on quality drivers, surge 2–4 kV L–N indoors and up to 6 kV in car parks, efficacy 120–160 lm/W depending on optic and drive current, L80/B10 50,000–100,000 h with ≤3-step SDCM. Planners tag sylvania batten luminaires when they want predictable inrush, neat dimming, and calm commissioning on shared phases.
Opal diffusers keep glare low in classrooms; micro-prism optics meet UGR ≤19 in office grids; linear rack lenses lift vertical illuminance on shelving; asymmetric wall-wash options handle corridors and displays. Output bands run ~2,000–18,000 lm; CRI 80 is standard with CRI 90 available for colour-critical zones; CCT 3000/4000/6500 K as the common set. Teams deploy sylvania led batten lights where approved photometrics must survive value-engineered swaps later in the programme.
Bodies are UV-stabilised PC or powder-coated aluminium with stainless fixings in salty or ammonia-rich air. Closed-cell EPDM or silicone gaskets, M20/M25 glands with locknuts, and breathable membranes maintain seal integrity in IP65/IP66 variants; IK08–IK10 is typical for service corridors. Through-wiring 3/5/7-pole with push-in cages 0.5…2.5 mm² keeps runs simple. On retrofit rails, installers choose sylvania surface mounted battens to reuse fixing centres and avoid re-drilling above finished ceilings.
Addressed DALI-2 handles scenes, groups, and run-hour reporting; broadcast keeps small rooms quick; 1–10 V supports legacy drivers; push-dim remains available. Corridor function holds 10–30% background with fade profiles and lux thresholds around 5–1000 lx. Gateways expose KNX or BACnet datapoints to the BMS. Designs that standardise on sylvania linear batten lighting keep presence, daylight, and emergency test logic on one chain without one-off scripts.
High-efficacy engines and daylight/presence control deliver quick kWh gains without changing cable topology. Standby draw is trimmed for sensor-led floors; PF stays ≥0.9 at nominal; ripple current meets office guidance. Compliance touchpoints: EN 60598 luminaire safety, EN 60529 IP, EN 62262 IK, EN 61347 driver safety, EN 62386 DALI-2, EN 61000-3-2 and EN 55015 EMC, EN 62471 photobiological. Energy teams specify sylvania energy saving batten fixtures when payback has to stand up in audit.
Education and offices target 300–500 lx with UGR control; meeting rooms use scene recall; stair cores run fade-to-standby for safe egress; healthcare prefers sealed faces for wipe-down; housing cores need vandal-resistant clips. Spacing criteria hinge on mounting height, wall reflectance, and vertical-lux targets near doors and signage. Schedulers mark sylvania indoor batten luminaires to keep lumen classes, optics, and CCT/CRI consistent across floors.
Food prep and wash bays need smooth faces and hose-down resilience; livestock buildings require ammonia-tolerant polymers; parking decks want wide beams with cut-off near walls; plant rooms benefit from stainless hardware and higher surge levels. Operating window is typically −25…+50 °C with model-specific derate curves. Maintenance teams group sylvania industrial batten lights by length, lumen pack, and mounting kit so spares move between areas without trim clashes.
Logistics aisles use narrow batten optics with masking near cross-gangways; retail lifts verticals on gondolas; car parks use sealed bodies with higher surge; social housing keeps standby levels at 10–30% for black-out safety. Always confirm trunking pitch and live-end orientation; keep emergency circuits upstream of dimming; preserve EMC with 360° braid clamps into metal housings.
Pricing aligns to room and aisle schedules and you see live EU stock before crews are booked. Quotes arrive in about an hour with EAN/MPN so variants stay locked. Your portal shows lead times, shipment status, and downloadable price lists with stability windows suited to phased programmes. Approved clients can use post-payment up to 30 days. We consolidate partials to cut freight, and your account manager cross-checks optic choice, dimming interface, surge level, trunking hardware, suspension data, emergency method, and label sets against your drawings so cartons land site-ready across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.