Factory aisles, food prep, wash bays, and livestock buildings punish fittings with moisture, dust, and chemical vapor. Enclosures in this family use sealed gear trays, captive stainless clips, and reinforced cable entries so crews can mount once and stop revisiting. Drivers sit on calm inrush, PF ≥0.9, and surge protection typically 4–6 kV L–N for long runs on metalwork. Where projects need a repeatable backbone, teams specify sylvania 3proof luminaires to keep geometry, wiring, and accessories consistent across phases.
Bodies are UV-stabilised PC or powder-coated aluminium with opal or prismatic diffusers; gaskets are closed-cell EPDM or silicone; glands are metric M20/M25 with locknuts and strain relief. Sealing holds at IP65/IP66 provided threads are fully seated and ferrules match jacket OD; IK08–IK10 covers knocks in service corridors. Through-wiring is common (3/5-pole, 1.5–2.5 mm²) with push-in cages. For hose-down lines, maintenance teams select sylvania waterproof luminaires so cleaning doesn’t collapse the seal after repeated cycles.
Lumen classes span ~2,000–18,000 lm with efficacies typically 120–150 lm/W depending on drive current and ambient. Optics include opal for low glare, linear batten lenses for racks, and asymmetric options to lift vertical lux on shelving. CCT 3000/4000/6500 K; CRI 80 standard, CRI 90 on request; ≤3-step SDCM for batch consistency. Emergency SKUs (maintained/non-maintained) follow EN 60598-2-22 with addressable test on DALI-2. Designers call out sylvania dustproof and vapour proof lights where approved photometrics must survive steam, sugar dust, or fine powders.
Interfaces cover DALI-2 broadcast/addressed, 1–10 V, and simple switched runs; corridor/standby profiles keep 10–30 % background without flicker. THD typically ≤15 % on quality drivers; ripple current stays within office/plant guidance. Cable entries accept braided-shield terminations for EMC; earth paths are short and direct. When lines mix sensors and runtime logging, planners fold these fittings into sylvania led industrial lighting so presence logic and energy reporting live on the same bus.
Food and beverage zones need smooth faces for wipe-down; livestock barns require ammonia-tolerant plastics and stainless fasteners; car parks want wide beams with cut-off near walls; wash bays prefer anti-mist covers that stay clear after heat shock. Ambient range typically −25…+50 °C with derate curves published per model. In repeated rooms, facilities standardise sylvania moisture resistant luminaires by length, lumen class, and mounting kit to stabilise spares.
Compliance references used across the range: EN 60598 (luminaires), EN 60529 (IP), EN 62262 (IK), EN 62386 (DALI-2), EN 61347/-2-13 (driver safety), EN 61000-3-2 and EN 55015 (EMC), EN 62471 (photobiological). Inrush and MCB curves are declared; PF ≥0.9 at nominal; standby draws trimmed for sensor-led floors. For coastal or chemical exposure, specify coated gear trays and stainless fixings. Where drawings state sylvania ip65 lighting fixtures, QA checks torque on clips and glands during acceptance to keep the rating honest.
Start with mounting method (ceiling/trunking/suspended), then lock lumen class, beam, and spacing to target vertical and horizontal lux. Confirm ambient, wash-down pressure, and chemicals; choose PC vs glass vs aluminium accordingly. Fix control method early: addressed DALI-2 where analytics matter, broadcast where speed matters, 1–10 V for legacy lines. Procurement tags sylvania durable led luminaires by EAN/MPN, length, lumen pack, CCT/CRI, interface, and kit so replacements don’t drift mid-programme.
Lengths 600/1200/1500 mm with single or twin-board engines; quick-release gear trays for service; end-to-end joiners and trunking brackets to keep lines straight. Accessories include anti-tamper clips, hanging kits, and daisy-chain jumpers that preserve IP when linked.
Manufacturing bays, logistics corridors, food processing, wash bays, car parks, and agricultural buildings. Keep emergency circuits upstream of dimming; maintain shielding continuity on control lines with 360° clamps; verify trunking pitch and live-end orientation on long runs. For livestock and chlorine environments, confirm polymer resistance with site chemistries before bulk release.
Pair with Sylvania sensors, control modules, and wall keys so presence, daylight, and manual override share one logic set. Use Sylvania mounting and gland kits to preserve IP after service; match with Sylvania panels or high-bays in adjacent zones to keep CCT/CRI and dimming behaviour unified.
We align pricing to area schedules and show live EU stock before crews are booked. Quotes land in about an hour with EAN/MPN so variants stay locked. Your portal tracks lead times, shipment status, and downloadable price lists with dependable validity windows. Approved clients can use post-payment up to 30 days. We consolidate partials to cut freight, and an account manager cross-checks optic choice, surge level, control method, mounting hardware, gland sets, gasket profiles, and through-wiring against your drawings so cartons arrive site-ready.