swit.act. 8-g 16 A man.act. + C-load KNX DRA
In stock: No
Vendor stock: No
Minimal order quantity: 1
Price (excl. VAT):
350,46 €
This price is valid until 24.12.25
Estimate delivery time at our warehouse (approx.):
4-6 weeks
Technical Information
Item condition |
New |
Manufacture name |
swit.act. 8-g 16 A man.act. + C-load KNX DRA |
Brand |
Gira
|
Categories |
Bus System Devices (KNX/Modbus)
|
Country of origin |
DE |
Harmonized System Code |
8536 4900 00
|
Bus system KNX |
Yes |
With bus connection |
Yes |
Bus system LON |
No |
Bus system KNX radio |
No |
Radio frequent bidirectional |
No |
Packing details
Packing level 1 |
4010337042273 |
Other Technical data
Mounting method |
DRA (DIN-rail adapter) |
Rated current |
0 A |
Output power |
0 W |
Bus system radio frequent |
No |
Bus system Powernet |
No |
Max. switching power |
0 W |
Max. number of switching contacts |
4 |
Number of digital inputs |
0 |
Width in number of modular spacings |
8 |
Max. switching current |
0 A |
Other bus systems |
None |
Suitable for C-load |
Yes |
Different phases connectable |
No |
Local operation/hand operation |
Yes |
Degree of protection (IP) |
IP20 |
With LED indication |
No |
Modular expandability |
No |
Bus module detachable |
No |
Min. depth of built-in installation box |
0 mm |
Max. switching power LED |
0 W |
Description
Switching actuator, 8-gang 16 A with manual actuation and current measurement for C-loads, for KNX DRA plus DRA switching actuators with integrated bus coupler. For switching independently controllable groups of loads. With manual switch for switching over the relay (On Off) parallel or without KNX operation. Multi-phase connection. No additional power supply required. Features: Manual actuation of the relay independent of the bus or switching position indication. NO contact or NC contact operation. Central switching function. Group feedback for reduction of bus load. Active or passive (object can be read out) cyclical feedback function. Feedback can be delayed until after the recovery of bus voltage. Logical linking function for each output. Block function can be parameterised for each channel. As an alternative, forced setting function for each output. Time functions (switch-on off delay, staircase light function – also with advance warning function). Integration in light scenes is possible, eight internal scenes at the most can be parameterised per channel. Memory function for light scenes. Elapsed operating time meter as forward backward counter with limit function (limit can be changed via bus) can be activated for each output. Input monitoring for cyclical updating with safety setting. Reactions in case of bus voltage failure and restoration can be set for each channel following an ETS programming process. The switching contacts of the switching actuator, 8-gang, C-load are especially designed for loads with a capacitive character, and therefore conditional, brief, high switch-on currents (see Technical Data). The switching actuator has an integrated current detection. A current measurement can be carried out for each channel. Current detection: Measurement of load current for each channel. Threshold values for load monitoring (e.g. signalling of load failure). Independent switching of the eight outputs. Notes : Installation on DIN top-hat rail. VDE approval in accordance with EN 60669-1, EN 60669-2-1.