Register to unlock your exclusive B2B prices and start shopping. Sign up now!
SPBT12-280-1+NPE50 Lightning current and surge arresters, 50kA, N-space unit image 1
SPBT12-280-1+NPE50 Lightning current and surge arresters, 50kA, N-space unit image 2
SPBT12-280-1+NPE50 Lightning current and surge arresters, 50kA, N-space unit thumbnail 1
SPBT12-280-1+NPE50 Lightning current and surge arresters, 50kA, N-space unit thumbnail 2

SPBT12-280-1+NPE50 Lightning current and surge arresters, 50kA, N-space unit

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
132,99 €
This price is valid until 24.12.25
EAN: 4015081787883
MPN: 184752
Package: 1
Box: 60
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name SPBT12-280-1+NPE50 Lightning current and surge arresters, 50kA, N-space unit
Brand EATON
Categories Surge Protection Devices (SPD)
Country of origin RO
Harmonized System Code 8536 5080 00
Lightning impulse current (10/350 µs) 12.5 kA
Voltage protection level 1.5 kV
Max. continuous voltage AC 260 V
Nominal voltage AC 240 V
Nominal voltage DC 0 V
Test class Type 1 + 2
Voltage protection level L-N 1.5 kV
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 1.4 kV
Voltage protection level L-PE 1.5 kV

Packing details

Packing level 1 4015081787883
Packing level 2 9008790796937

Other Technical data

Mounting method DIN rail (top hat rail) 35 mm
Number of poles 2
Construction size 2 modular spacing
Remote signalling No
Follow current extinguishing capability 0 kA
Signalling at the device Optic
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 35 mm²
Voltage protection level (DC+ - DC-) 0 kV
Voltage protection level (DC+/DC- - PE) 0 kV
Specific energy (W/R) 625 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment No
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other Yes
System configuration TN-C-S No
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Voltage switching spark gap technology Yes
Overcurrent protected voltage tapping No

Description

For protecting consumer systems against transient overvoltages caused by direct and indirect lightning strikes and switching operations, use in accordance with IEC 60364-5-53 section 534, iI according to IEC 61643-1, SPD-type T1, T2 according to EN 61643-11, lightning protection classes III and IV as per IEC 62305