| Item condition |
New |
| Manufacture name |
Stratos MAXO 32/0,5-16 PN6/10 |
| Brand |
WILO
|
| Categories |
Pump Systems & Units
|
| Country of origin* |
DE |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Harmonized System Code |
8413 7030 00
|
| ETIM |
EC010980
|
| Nominal current |
2.23 A |
| Number of phases |
1 |
| Max. discharge flow |
21.02 m³/h |
| Max. static height |
16.1 m |
| Flange shape |
Round |
| Ambient temperature |
-10 °C |
| Supporting protocol for PROFIBUS |
No |
| Supporting protocol for KNX |
No |
| Potential free switch contact |
Yes |
| Rated voltage |
230 V |
| Built-in length |
220 mm |
| Frequency |
50/60 Hz |
| Degree of protection (IP) |
IPX4D |
| Radio standard Bluetooth |
Yes |
| Radio standard Wi-Fi 802.11 |
No |
| With communication interface RS-232 |
No |
| With communication interface RS-485 |
Yes |
| Supporting protocol for EtherNet/IP |
No |
| Supporting protocol for PROFINET IO |
No |
| Pump power consumption (solpump) |
510 W |
| Pump power consumption standby (solstandbypump) |
10 W |
| Material impeller/pump wheel |
Polypropylene (PP) |
| Motor power input (P1) per motor |
0.51 kW |
| Volume flow rate (BEP) |
11.03 m³/h |
| Discharge head at flow rate (BEP) |
94 kPa |
| Connection standard inlet side |
EN 1092-2 |
| Connection standard outlet side |
EN 1092-2 |
| Radio standard 2G / 3G / 4G |
No |
| Radio standard 5G |
No |
| Interface signal 0-10 V / 2-10 V |
Yes |
| Interface signal 0-20 mA / 4-20 mA |
Yes |
| Interface PT100 / PT1000 / PTC |
Yes |
| Interface Pulse Width Modulation (PWM) |
No |
| Interface pulse counter |
No |
| Supporting protocol for CAN/CANOpen |
No |
| Supporting protocol for Modbus TCP |
No |
| Supporting protocol for Modbus RTU |
No |
| Supporting protocol for BACnet MS/TP |
No |
| Supporting protocol for BACnet IP |
No |
| Supporting protocol for LON/LONWorks |
No |
| Supporting protocol for LIN Bus |
No |
| Radio standard 2G |
No |
| Radio standard 3G |
No |
| Radio standard 4G |
No |
| Motor speed control |
Built-in |
| Max. operating pressure |
10 bar |
| Material pump casing |
Cast iron |
| Double pump |
No |
| Insulation class according to IEC |
F |
| Material quality pump casing |
Cast iron GG 25 (GJL-250) |
| Medium temperature (continuous) |
-10 °C |
| Material quality impeller/pump wheel |
PP-GF |
| Connection inlet side |
Flange |
| Nominal diameter connection inlet side |
DN 32 |
| Nominal diameter connection outlet side |
DN 32 |
| Outer pipe diameter connection inlet side |
32 mm |
| Outer pipe diameter connection outlet side |
32 mm |
| Connection outlet side |
Flange |
| Energy Efficiency Index (EEI) |
0.18 |
| Flange compression stage connection inlet side |
PN 6 |
| Flange compression stage connection outlet side |
PN 6 |