Register to unlock your exclusive B2B prices and start shopping. Sign up now!

Stanley Switches and sockets

stanley switches and sockets — range map

The family is built around Euro back-box geometry (60 mm), with 60/71 mm screw centres and consistent trim lines across series. Mechanisms cover 1-way/2-way/intermediate, momentary (bell), key-switch, indicator and rotary dimmer inserts. Face options: slim flat plates for modern fit-outs, classic bevel for hospitality, and gasketed utility fronts for wet-cleaned zones. Current classes: 10AX/16AX general lighting, 20AX for fans and small inductive loads. Decorative frames arrive in satin white, graphite, brushed aluminium and glass; pro lines use metal subframes for tighter tolerances and cleaner plate alignment.

stanley electrical switches — mechanisms and ratings

Contact sets use silver-alloy tips with cam profiles sized for LED drivers (suppressed arcing on part-load). Toggle/rocker/flat paddles share a common carrier; locator LEDs and neon indicators are available where night finding matters. Trailing-edge dimmer modules: 5–200 W(LED) typical, soft-start, min-level trim, thermal foldback; push-dim or rotary in the same aperture. Back-pressure springs are matched across gangs so mixed circuits still feel consistent. Compliance: EN/IEC 60669-1 (-2-1 for electronic dimmers); plastics glow-wire 650–850 °C (IEC 60695-2-11/-12).

stanley wall sockets — standards and options

Outlet geometry follows regional practice: Type F (Schuko) with earthing clips, Type E/F hybrid for FR/BE pins, and Type G where required. Shutters on all public-area variants. Contact sleeves are nickel-plated brass; terminals accept 2×2.5 mm² for ring finals. Combination plates add USB power: A+A 2.4 A shared, A+C 18–30 W USB-C PD, or C-only 45–65 W where laptops charge at the wall. Thermal and short-circuit protection sit on the DC board; standby draw <0.1 W. For bathrooms and housekeeping routes, snap-in gasket frames lift the front to IP44 when paired with the correct box and cover.

stanley modular wiring devices — frames and finishes

The grid takes switch, dimmer, outlet, data/AV and blanking inserts behind 1–4-gang frames so one palette serves guest, office and back-of-house without colour drift. Horizontal multi-frames use a hidden joiner to keep grout lines true across tiled walls. Trim depths: slim (≈7–9 mm proud) or classic (≈11–13 mm). Captive screws and anti-rotation nibs prevent plate creep. Blind and labelled key-switch modules (maintained or momentary) are available for HVAC isolate, maid/Do-Not-Disturb, and plant override.

Wiring geometry, IP and impact behaviour

Terminals: screw-clamp or spring-cage with ferrule entry; 1.5…2.5 mm² Cu conductors. Depth: ≈22–26 mm (basic switch), 28–32 mm (USB/dimmer). Face and module sets are IP20 by default; utility fronts + gasket frames present IP44 in the correct zones. Impact to IK06–IK08 depending on finish; metal trims ship with insulating backers to preserve creepage/clearance.

Dimming and driver reality on site

LED channels behave best on trailing-edge (RC); leading-edge (RL) variants exist but expect more acoustic buzz on small loads. Keep each plate’s aggregate within the dimmer’s stable window; very light channels can shimmer—add a bleed or move loads. Label the dimmer topology on the drawing so commissioning teams don’t mix RL/RC across one floor.

USB power and EMC hygiene

USB-C PD modules negotiate 5/9/12/15/20 V profiles with temperature foldback. Use separate conduit for SELV; where AV sits nearby, add 360° braid clamps at entry to keep noise out of control trays. These combinations are often listed by buyers under stanley power outlets when USB is part of the requirement—note PD wattage in the same line.

Series overview installers actually pick

  • Core White — everyday backbone for apartments/offices; 10AX/16AX rockers, Schuko/hybrid sockets, optional A+C USB.
  • Metal Line — brushed aluminium/stainless trims on metal carriers; higher IK, matching key-switches and legend windows for corridors.
  • Glass Edge — low-profile glass faces with rotary/push dimmers; clean look for front-of-house.
  • Utility IP44 — gasketed frames, cover flaps and high-grip rockers for housekeeping and wash-adjacent positions.
    Where tenders use consumer wording like stanley plug sockets, map it to the outlet module from the series above and lock Type (F/E-F/G) in the notes.

Applications and fit cues

Guestrooms: Core White or Glass Edge; 2700–3000 K dimmer channels on bedside and pendants, USB A+C near the desk. Open offices: Core White with 4000 K circuits, 16AX on switching, higher-power USB-C PD at collaborative tables. Retail front-of-house: Glass Edge with dimmers for accent lines; ensure plate datum aligns to tile grout. Plant/utility: Utility IP44 with flaps, 20AX mechanisms on fans/contactors.

Box depth and termination cheatsheet

  • Single-gang switch: 25 mm box is workable; 35–40 mm is nicer for multi-gang or indicator wiring.
  • USB/dimmer combos: use 40 mm boxes to avoid conductor pinch.
  • Ring finals: keep conductor bend radii generous; back-out terminals once after IR testing to relax whiskers.

Standards snapshot buyers expect

Switches: EN/IEC 60669-1/-2-1. Socket-outlets: EN/IEC 60884-1. USB power: EN/IEC 62368-1; EMC EN 55015/EN 61000-6-1/-6-3; mains quality EN 61000-3-2/-3-3. Plastics glow-wire 650–850 °C. Clear laser-etch on the rear indicates AX rating, terminal scheme and torque.

Selection checklist for specifiers

  1. Plate line (Core/Metal/Glass/Utility) and finish.
  2. Mechanism set per gang (1-way/2-way/intermediate, dimmer type, indicator).
  3. Outlet standard (F/E-F/G) and USB spec (A+C 30 W, C 45–65 W etc.).
  4. IP/IK requirement by room; gasket/cover where needed.
  5. Box depth and conductor plan; terminal style (screw vs spring-cage).
  6. Legends and key-switch need for plant or guest controls.

Procurement notes and kitting

Quote each plate as “frame finish + mechanism set + box depth note.” For outlets, include standard and USB PD wattage. For dimmers, state trailing-edge and LED W capacity plus minimum level. When a basket line groups frames, glands, labels and gaskets as stanley installation accessories, keep the finish and thread/gland sizes aligned with the enclosure and publish torque windows—cartons land site-ready and first-fix moves faster.