STANDSCHAK. BODY M16 NC/NC
In stock: No
Vendor stock: No
Minimal order quantity: 1
Price (excl. VAT):
11,59 €
This price is valid until 24.12.25
Estimate delivery time at our warehouse (approx.):
8-10 weeks
Technical Information
Item condition |
New |
Manufacture name |
STANDSCHAK. BODY M16 NC/NC |
Brand |
Telemecanique
|
Categories |
Limit Switches
|
Country of origin |
ID |
Harmonized System Code |
8536 5080 00
|
Switching function |
Slow-action switch with overlapping |
Rated operation current Ie at AC-15, 230 V |
1.5 A |
Rated operation current Ie at DC-13, 230 V |
0.1 A |
Suitable for safety functions |
No |
With status indication |
No |
Type of control element |
None |
Rated operation current Ie at AC-15, 24 V |
0 A |
Rated operation current Ie at DC-13, 125 V |
0 A |
Rated operation current Ie at DC-13, 24 V |
0 A |
Packing details
Packing level 1 |
3389110184600 |
Other Technical data
Housing material |
Plastic |
Coating housing |
Other |
Type of interface for safety communication |
None |
Type of electric connection |
Cable entry metrical |
Explosion safety category for gas |
None |
Explosion safety category for dust |
None |
Construction type housing |
Cuboid |
Degree of protection (IP) |
IP66/IP67 |
Forced opening |
Yes |
Number of safety auxiliary contacts |
0 |
Type of interface |
None |
Output electronic |
No |
Rated operation current Ie at AC-15, 125 V |
0 A |
Width sensor |
58 mm |
Diameter sensor |
0 mm |
Height of sensor |
51 mm |
Length of sensor |
30 mm |
Switching function latching |
No |
Ambient temperature during operating |
-25-70 °C |
Number of contacts as normally closed contact |
2 |
Number of contacts as normally open contact |
0 |
Number of contacts as change-over contact |
0 |
Alignment of the control element |
Other |
Description
This body, is part of the XCKT offer, a range of compact design, plastic, limit switches with 2 cable entries. It is a fixed body, with 2 entries tapped M16 x 1.5 for ISO cable gland. Contacts: 2 NC, simultaneous, slow break. A wide range of heads/operators, is compatible with this body.