Technical Information
Item condition |
New |
Manufacture name |
Standard room thermostat with display TRDLS1790SW |
Brand |
Jung
|
Categories |
Control devices for switches and sockets
|
Country of origin |
DE |
Harmonized System Code |
9032 1080 00
|
Colour |
Black |
Width |
71 mm |
Height |
71 mm |
Depth |
0 mm |
RAL-number |
9005 |
Connection |
3-/4-wire |
With display |
Yes |
With thermal feedback |
No |
Measuring range |
5-30 °C |
Operation |
Button |
Explosion-proof |
No |
Type of clock |
Week clock |
Degree of protection (IP) |
IP20 |
Sensor/feeler type |
Resistance sensor |
Standby power consumption (solstandby) |
0.24 W |
Max. contact voltage |
230 V |
With receiver |
No |
Weather-dependent control system |
No |
With tap water circuit |
No |
Number of heater outputs |
1 |
Number of cooler outputs |
1 |
Clock model |
Digital |
Selector switch for heating and heating with hot water |
No |
Overtime switch |
No |
Temperature readable |
Yes |
Optimisation |
Yes |
Number of switching programmes |
3 |
Suitable for heating |
Yes |
Max. contact load |
16 A |
Differential value |
-0.5-0.5 K |
External sensor |
Yes |
Adjustable differential |
No |
Packing details
Packing level 1 |
4011377172234 |
Downloads
Description
This is a standard digital room thermostat with an integrated display, designed for controlling heating or cooling systems.It connects via a 3-/4-wire setup and uses resistance sensor technology for temperature measurements. Dimensions:71 mm width x 71 mm height.Color:Black (RAL 9005).Standby power consumption:0.24 W.Temperature control range from 5.000°C to 30.000°C;differential value adjustable between -0.500 K and 0.500 K but not externally configurable. Suitable for single heating output (1), includes week clock functionality (type:Digital).Max contact load rated at 16 A, max voltage at terminal points up to 230 V. With thermal feedback disabled, regulation features on/off only but optimized settings are supported by design protocol specifics without external receiver dependency. Switching programs count stands at three programmable profiles per design limits;no provision exists for hot water interaction or weather conditions linked adjustments beyond standalone application datasets articulated pre-install protocols as defined above systems function performance tests했습니다