Register to unlock your exclusive B2B prices and start shopping. Sign up now!
SPD type 2, 3 phase/3 varistors/1000VDC Max./remote signal./15kA (7P.23.9.000.1015) image 1
SPD type 2, 3 phase/3 varistors/1000VDC Max./remote signal./15kA (7P.23.9.000.1015) image 2
SPD type 2, 3 phase/3 varistors/1000VDC Max./remote signal./15kA (7P.23.9.000.1015) image 3
SPD type 2, 3 phase/3 varistors/1000VDC Max./remote signal./15kA (7P.23.9.000.1015) thumbnail 1
SPD type 2, 3 phase/3 varistors/1000VDC Max./remote signal./15kA (7P.23.9.000.1015) thumbnail 2
SPD type 2, 3 phase/3 varistors/1000VDC Max./remote signal./15kA (7P.23.9.000.1015) thumbnail 3

SPD type 2, 3 phase/3 varistors/1000VDC Max./remote signal./15kA (7P.23.9.000.1015)

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
149,54 € per pcs
This price is valid until 31.12.25
EAN: 8012823368498
MPN: 7P2390001015
Package: 1
Estimate delivery time at our warehouse (approx.): 1-4 weeks

Technical Information

Item condition New
Manufacture name SPD type 2, 3 phase/3 varistors/1000VDC Max./remote signal./15kA (7P.23.9.000.1015)
Brand FINDER
Categories Surge Protection Devices (SPD)
Country of origin CZ
Harmonized System Code 8535 4000 00
Voltage protection level 3.6 kV
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 230 V
Voltage protection level L-N 1.2 kV
Degree of protection (IP) IP20
Max. PV-voltage 420 V
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C-S Yes

Packing details

Packing level 1 8012823368498

Other Technical data

Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 2
Construction size 3 modular spacing
Max. continuous voltage AC 275 V
Category type 2 Yes
Signalling at the device Optic
Max. continuous voltage DC 350 V
Voltage protection level N-PE 1.2 kV
Integrated backup fuse No
System configuration TN-C Yes
System configuration TN-S No
System configuration TT No
System configuration other No
Max. discharge surge current (8/20) 30 kA
Max. overcurrent protection device, parallel connection (fuse) 160 A

Downloads

Description

Surge protection device Mounting method: DIN rail (top hat rail) 35 mm With remote signalling contact: yes Number of conductors (without earthing): 3 Construction size: 3 modular spacing Max. continuous voltage AC: 275 V. Nominal discharge surge current (8/20): 20 kA. Nominal voltage AC: 230 V. Category type 2: yes Voltage protection level L-N: 1.2 kV. Signalling at the device: Optic Max. continuous voltage DC: 350 V. Protection category: IP20 Max. PV-voltage: 420 V. Voltage protection level N-PE: 1.2 kV. Integrated backup fuse: no System configuration DC: no System configuration IT: no System configuration TN: yes System configuration TN-C: yes System configuration TN-S: no System configuration TT: no System configuration other: no System configuration TN-C-S: yes Max. discharge surge current (8/20): 30 kA.