Register to unlock your exclusive B2B prices and start shopping. Sign up now!
SPD type 1+2/N-PE spark-gap for 3 phase system/255V Max. (7P.09.1.255.0100) image 1
SPD type 1+2/N-PE spark-gap for 3 phase system/255V Max. (7P.09.1.255.0100) image 2
SPD type 1+2/N-PE spark-gap for 3 phase system/255V Max. (7P.09.1.255.0100) image 3
SPD type 1+2/N-PE spark-gap for 3 phase system/255V Max. (7P.09.1.255.0100) thumbnail 1
SPD type 1+2/N-PE spark-gap for 3 phase system/255V Max. (7P.09.1.255.0100) thumbnail 2
SPD type 1+2/N-PE spark-gap for 3 phase system/255V Max. (7P.09.1.255.0100) thumbnail 3

SPD type 1+2/N-PE spark-gap for 3 phase system/255V Max. (7P.09.1.255.0100)

Order only Minimal order quantity: 5
Price (excl. VAT):
326,69 € per pcs
This price is valid until 31.12.25
Subtotal: 1 633,45 € MOQ: 5
EAN: 8012823354286
MPN: 7P0912550100
Package: 1
Estimate delivery time at our warehouse (approx.): 1-4 weeks

Technical Information

Item condition New
Manufacture name SPD type 1+2/N-PE spark-gap for 3 phase system/255V Max. (7P.09.1.255.0100)
Brand FINDER
Categories Surge Protection Devices (SPD)
Country of origin* CZ
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8536 3030 00
Nominal discharge surge current (8/20) 100 kA
Degree of protection (IP) IP20
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C-S No

Packing details

Packing level 1 8012823354286

Other Technical data

Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact No
Number of conductors (without earthing) 1
Construction size 2 modular spacing
Max. continuous voltage AC 255 V
Category type 2 No
Signalling at the device Optic
Voltage protection level N-PE 1.5 kV
Integrated backup fuse No
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other Yes
Max. discharge surge current (8/20) 100 kA
Leakage-current free Yes

Downloads

Description

Surge protection device Mounting method: DIN rail (top hat rail) 35 mm With remote signalling contact: no Number of conductors (without earthing): 1 Construction size: 2 modular spacing Max. continuous voltage AC: 255 V. Nominal discharge surge current (8/20): 100 kA. Category type 2: no Signalling at the device: Optic Protection category: IP20 Voltage protection level N-PE: 1.5 kV. Integrated backup fuse: no System configuration DC: no System configuration IT: no System configuration TN: no System configuration TN-C: no System configuration TN-S: no System configuration TT: no System configuration other: yes System configuration TN-C-S: no Max. discharge surge current (8/20): 100 kA.