Siemens Fuses

siemens fuses range and application classes

Siemens covers the full arc from small control loops to LV main incomers. Cartridge sizes include 10×38 and 14×51 for auxiliaries, NH00…NH3 for distribution and motor feeders, and semiconductor protection in aR with low I²t let-through. Application classes are the familiar set: gG (general purpose full-range), aM (motor back-up), gPV for strings and combiner boxes, and aR for drives/rectifiers. Typical breaking capacities sit at 80–120 kA at 400/500 V AC and up to 100 kA at 690 V AC on NH frames; 10×38 control fuses commonly reach 20–50 kA depending on series. Indicators are pin, striker, or microswitch-ready for remote signalling. Expect published watt-loss per size so thermal budgets in enclosed switchboards are credible.

siemens fuse holders footprints and wiring

Footprints span 1-pole 10×38 DIN holders up to 3-pole 14×51, plus switch-disconnector bodies for NH sizes (00…3) that mount on rail or directly on busbar systems. Touch-safe finger guards and IP20 shutters are standard; IP30/IP40 fronts are available for cabinet doors. Terminations accept 0.75…25 mm² on cartridge holders and up to 120 mm² on NH studs; torque windows are printed on the device. Many bodies support cage, box-lug, or spring clamp. Optional phase barriers, doored covers, and mechanical interlocks keep live parts isolated when the knife is open. For cabinet builders, through-feed jumpers reduce cross-wiring across multi-pole control rows.

siemens protection devices coordination and ratings

Selectivity and back-up coordination data is provided against Siemens MCCBs/MCBs and motor starters. gG upstream with aM downstream remains the usual pattern for motors: the back-up class rides out inrush while the feeder fuse clears heavy faults with low let-through. Semiconductor aR parts publish pre-arcing I²t and total I²t for every rating, so you can check drive SCR/IGBT limits rather than guessing. Thermal derating curves versus ambient and enclosure size are part of the datasheets; at 50–60 °C boards, upsize one or move air. Standards alignment is IEC/EN 60269 for links, UL 248 where dual listing matters, and IEC 60947-3 for switch-disconnectors. Assembly builders reference IEC 61439 for temperature rise across fuseways and copperwork.

siemens fuse links technical parameters

  • Voltage classes: 400/500/690 V AC on NH; 1500 V DC options for PV strings and battery racks.
  • Current ranges: 0.5–32 A (10×38), 2–50 A (14×51), 6–630 A (NH00…NH3) with extended frames to 1250 A.
  • Power loss: published per size (e.g., 10×38 at 2–3 W, NH1 around 8–12 W at In) for heat maps.
  • Indicators: centre-dot, striker pin for microswitches, or lateral flags visible behind windows.
  • Let-through: time-current curves and I²t enable cable and busbar thermal checks; energy-based selectivity tables are included for common breaker pairs.

Other Siemens products

BATERIE AKU SAFT 3,6V Li LS26500 R14
Safety relay 3TK28 emergency stop 24V AC 0.05-3s delay
BEZP.KOMBINACE SIEMENS 3TK2826-1CW30
Safety relay 3TK28 24V DC 2NO+1NC
Safety switch 3SE2 metal housing 2NC+1NO 1 cable entry M20

Applications and integration with boards and MCCs

Control and instrumentation panels use 10×38 holders for 24 V DC rails, analogue loops, relays, and IO-Link masters—fast fault finding when channels are fused per slice. Motor control centres pair NH aM on the starter tier with gG upstream on the section bus. Semiconductor drives get aR on the DC link to protect rectifiers and braking choppers; match I²t to the drive manufacturer’s table. PV combiner boxes land gPV links with string-level touch-safe holders and busbar-mount disconnectors on the main. Rail and mining skids lean on NH switch-disconnectors with visible break and padlockable handles. For retrofits, adapter sets let you land new bodies on legacy drilling lines without re-punching copper.

Selection guidelines for B2B buyers

Start with the duty: gG for general feeders, aM for motors, aR for power electronics, gPV for solar. Fix system voltage and fault level, then choose a frame with the required breaking capacity margin. Size by conductor thermal limit and motor inrush profile, not just nameplate. Check time-current curves against downstream MCB/MCCB to preserve selectivity at the fault levels you actually have. In hot boards or sealed cubicles, use the watt-loss figures to confirm the temperature rise fits IEC 61439 allowances. When building strings of 10×38, standardize one holder family with blown-fuse microswitches; it halves fault-finding time on large cells. On NH gear, decide early if you want switch-disconnector style (knife + handle) or fixed bases with pullers—service rules and arc-flash policy usually dictate this.

Engineering notes that avoid rework

  • Respect torque on NH studs; loose joints cook knives and drift thermals in compliance tests.
  • Publish a single table of spare link ratings per section; mixed spares create mis-coordination after the first call-out.
  • For DC rails, confirm the link’s DC interruption rating and polarity behaviour; not every AC gG link is DC-capable at the same current.
  • Use striker-ready links where remote alarms or PLC inputs will be wired later; retrofitting microswitch lids on a live plant is never fun.
  • In battery rooms and PV, check enclosure material and creepage distances—condensation moves failure points.

siemens circuit protection in mixed architectures

Plants rarely run one method. It’s common to place MCCBs on incomers and section feeders, then fan out with NH on outgoing ways for motors, VFDs, and heaters. That mix keeps breaking capacity where it belongs and uses fuses for low let-through near sensitive loads. Siemens publishes coordination charts between breakers and links so you can prove selectivity zone by zone instead of de-rating everything “just in case.” This is the core of well-designed siemens electrical protection systems in brownfield sites.

Compliance and control integration

Fuse switch-disconnectors with auxiliary contacts report open/tripped to PLCs; use those on guarded machines where maintenance needs confirmation before entry. For safety outputs that must go dark fast, low-energy let-through from siemens safety fuses reduces arc stress on downstream wiring and contactors. IO tables should include every auxiliary and striker microswitch tag so diagnostics show the exact feeder, not a generic alarm.

Procurement notes: order holders and links as matched sets and list striker/microswitch options in the PO text. For PV and battery, specify gPV voltage class and temperature range. Where MCC sections repeat, pre-kit NH handles, shrouds, phase barriers, and labels by cubicle so crews aren’t hunting small parts.

Advantages of working with Bankoflamps

We align fuse classes, frames, and holder styles to your one-line and thermal study, then confirm live EU stock before outages are scheduled. Quotes arrive fast with EAN/MPN so voltage class, breaking capacity, indicator type, and accessory packs don’t drift mid-phase. Your portal shows lead times, shipment progress, and downloadable price lists; pricing validity tracks project gates. Approved clients can use post-payment up to 30 days. We consolidate by board section to cut freight and site sorting, and your account manager cross-checks coordination tables, I²t limits, torque data, busbar pitch, and handle kits against your drawings—so crates land board-ready and electricians fit once.