Siemens Motor Controls and Drives

siemens control gear for panels and MCCs

Built for continuous duty in real switchboards, Siemens gear lands on 35 mm DIN rail, publishes honest thermal data, and gives installers push-in or screw terminals that actually swallow 0.5…6 mm² without mangling strands. Voltage classes cover 230/400/690 V AC and 24 V DC control; impulse withstand is typically 4 kV across control circuits. Isolation and clear marking let panel techs trace L/N/PE and A1/A2 quickly during FAT and maintenance.

siemens motor control gear functions and ratings

Across feeders you’ll use three blocks: a motor-protective circuit breaker (MPCB) for short-circuit + thermal protection, a contactor sized to AC-3 duty, and an overload (thermal Class 10/20 or electronic with phase-loss/unbalance). Frame ranges hit 0.12…75 kW at 400 V with contactors graded 9…95 A AC-3 in compact widths; coils arrive 24 V DC and 110/230 V AC with low inrush “UC” options for dense boards. Reversing and star-delta assemblies ship as matched kits with mechanical interlock and pre-tested coordination to IEC/EN 60947-4-1.

Other Siemens products

CENTR.JEDN. SIMATIC 6ES7216-2AD23-0XB0
PLC CPU unit SIMATIC S7-1200 CPU 1216C DC/DC/DC 24V 14DI 10DO 2AI
Residual current circuit breaker 5SM3 16A 1P+N 30mA 230V
Motor contactor 3RT1 3-pole 5.5kW 24V AC coil
Digital time switch 7LF4 weekly program 1 channel 230V

siemens contactors and relays families and coils

Power contactors carry AgSnO₂ tips for arc endurance and list electrical life in AC-3 (100–1 000 k cycles by frame). Auxiliary contact blocks provide mirror contacts for safety feedback; mechanical interlocks prevent opposite command closure on reversing pairs. Interface relays come as 6–12 mm blades (1CO/2CO) with LED/suppression built-in—ideal between PLC 24 V outputs and valves or beacons. Solid-state relays handle high-cycle loads and fast solenoids; check Rθ and add heatsinks above 40 °C panel ambient.

siemens switchgear components protection and auxiliaries

Add-ons include shunt-trip and undervoltage releases for MPCBs, surge-proof coil suppressors, clip-on auxiliary contacts (NO/NC), door-coupling rotary handles, and mechanical interlocks. Soft starters bridge DOL to VFD by trimming inrush and mechanical shock; select current limit and kick-start to match the load. Control transformers (230/400→110/24 V) meet IEC/EN 61558 with short-circuit protection notes for secondary circuits. For e-stops and permissives, positive-opening NC on pushbuttons satisfies IEC/EN 60947-5-1 and -5-5.

Technical specifications and standards

  • Utilization categories: AC-1/AC-3/AC-4 are published per size; use AC-3 for standard squirrel-cage motors and AC-4 only when plugging/jogging is unavoidable.
  • Coordination: Type 1/Type 2 tables pair MPCB + contactor + overload to limit let-through energy and preserve contacts after faults.
  • Thermals: each device declares power dissipation; follow spacing/derating curves at 45–60 °C boards and altitude >2 000 m.
  • Control circuits: 24 V DC logic meets IEC/EN 61131-2 input thresholds; coil economy electronics reduce holding VA on UC coils.
  • Compliance: IEC/EN 60947-1 general rules; -2 for breakers, -4-1 for contactors/overloads, -5-1 for control devices; assemblies to IEC/EN 61439 heat-rise limits.

Applications and integration

Packaging and intralogistics: reversing starters with electronic overloads, interlocked guards on PROFIsafe, and IO-Link auxiliaries for diagnostics. HVAC skids: MPCB + contactor + Class 10 overload on fans and pumps, with door handles and padlock kits for LOTO. Machine tools: AC-3 frames with RC snubbers near VFDs to keep EMC sane; use mirror contacts for reliable EDM. Food & beverage: stainless hardware and IP54/55 enclosures around door gear; select coated PCBs for wash-adjacent zones.

Integration with siemens industrial control units

Starters drop neatly beside S7-1200/1500 and ET 200 slices; OF/SD contacts signal trips to the PLC, and power meters expose kW/kWh so you can tighten overload settings based on measured, not assumed, currents. X-coded M12 or RJ45 runs sit in segregated trunking; 360° shield clamps at entry plates keep drive noise out of the control bay.

Selection guide for B2B buyers

  1. Load and duty: nameplate kW, FLA, starts/hour, and whether braking or jogging exists—this fixes AC-3 frame and overload class.
  2. Fault level & coordination: read Ik at the board and select Type 2 where downtime costs; verify with Siemens tables.
  3. Environment: ambient, enclosure size, altitude, and chemistry; apply thermal derating and use coated electronics where required.
  4. Control philosophy: coil voltage (24 V DC is cleanest), mirror contacts for safety, and interface relays for PLC isolation.
  5. Serviceability: push-in terminals, common auxiliaries, and door handles with clear legend plates cut MTTR.
  6. Networked diagnostics: consider electronic overloads with trip codes via PROFINET or hardwired OF/SD for SCADA clarity.
    Where specs group starters, pilots, and PLCs as siemens electrical control equipment, reserve rail space and backplane current from day one.

Engineering notes that prevent callbacks

  • Size MPCB to cable thermal limit, not just FLA; tighten to the cable chart after commissioning measurements.
  • Publish one coil voltage per row; mixed 24 V DC and 230 V AC is how night-shift mis-picks happen.
  • Place surge suppression at the coil and at inductive loads; it extends relay life and calms EMC.
  • Keep 30 % spare I/O and two blank rail pitches per cubicle—late adds always appear.
  • In VFD panels, route motor leads away from control gear; cross at 90° and bond shields 360°.

Where to deploy siemens automation control gear

Cells needing rapid changeovers benefit from modular feeders with plug-in auxiliaries and pre-wired interlocks; conveyor zones standardize one contactor frame and overload range to keep spares lean. For OEM skids exported globally, specify dual-listed devices and wide-range UC coils.