Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 1
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 2
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 3
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 4
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 5
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 6
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 7
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 8
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 9
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 10
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 11
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 12
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 13
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 14
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 15
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 16
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 17
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 18
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths image 19
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 1
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 2
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 3
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 4
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 5
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 6
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 7
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 8
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 9
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 10
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 11
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 12
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 13
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 14
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 15
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 16
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 17
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 18
Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths thumbnail 19

Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
215,51 €
This price is valid until 24.12.25
EAN: 4015081755677
MPN: 180413
Package: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths
Brand EATON
Categories Safety Relays
Country of origin DE
Harmonized System Code 8536 4900 00
Model Basic device
Number of outputs, safety related, undelayed, with contact 0
Type of electric connection Screw connection
Rail mounting possible Yes
Type of safety according to IEC 61496-1 None
Performance level according to EN ISO 13849-1 Level e
SIL according to IEC 61508 3

Packing details

Packing level 1 4015081755677

Other Technical data

Width 22.5 mm
Height 99 mm
Depth 114.5 mm
Release-delay 0 s
With approval according to UL Yes
With detachable clamps Yes
With start input No
With feedback circuit Yes
Number of outputs, safety related, delayed, with contact 0
Number of outputs, safety related, undelayed, semiconductors 0
Number of outputs, safety related, delayed, semiconductors 0
Number of outputs, signalling function, undelayed, with contact 1
Number of outputs, signalling function, delayed, with contact 0
Number of outputs, signalling function, undelayed, semiconductors 0
Number of outputs, signalling function, delayed, semiconductors 0
Rated control supply voltage at AC 50 Hz 20.4-26.4 V
Rated control supply voltage at AC 60 Hz 20.4-24 V
Rated control supply voltage at DC 24 V
With muting function No
With approval for BG BIA No
Suitable for monitoring of magnetic switches No
Suitable for monitoring of proximity switches No
Suitable for monitoring of emergency-stop circuits Yes
Suitable for monitoring of optoelectronic protection equipment No
Suitable for monitoring of position switches Yes
Suitable for monitoring of tactile sensors No
Suitable for monitoring of valves No
Stop category according to IEC 60204 0 (zero)
Voltage type for actuating AC/DC
Evaluation inputs One- and two-channel
With approval for TÜV Yes

Description

Safety relay for implementing emergency stop / protective door and light curtain monitoring basic functions up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single-channel or dual-channel operation, 3 enable current paths, input rated voltage 24 V AC/DC

Similar items

Accessories

Suitable for