Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Residual current breaker RCBO DS200 RANGE 10kA, 2P, A, curve C,  6A, 3 image 1
Residual current breaker RCBO DS200 RANGE 10kA, 2P, A, curve C,  6A, 3 image 2
Residual current breaker RCBO DS200 RANGE 10kA, 2P, A, curve C,  6A, 3 thumbnail 1
Residual current breaker RCBO DS200 RANGE 10kA, 2P, A, curve C,  6A, 3 thumbnail 2

Residual current breaker RCBO DS200 RANGE 10kA, 2P, A, curve C, 6A, 3

Order only
Price (excl. VAT):
402,43 €
This price is valid until 28.02.26
EAN: 8012542079934
MPN: 2CSR272199R1064
Package: 1
Box: 5
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name Residual current breaker RCBO DS200 RANGE 10kA, 2P, A, curve C, 6A, 3
Brand ABB
Categories RCBO - (Earth Leakage Breakers)
Country of origin* IT
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8536 3010 00
Rated current 6 A
Rated voltage 230 V
Release characteristic C
Rated fault current 0.03 A
Leakage current type A
Degree of protection (IP) IP2X
Number of protected poles 2
Ambient temperature during operating -25-55 °C
Number of poles (total) 2

Packing details

Packing level 1 8012542079934
Packing level 2 8012542079934

Other Technical data

Voltage type AC
Built-in depth 69 mm
Rated insulation voltage Ui 500 V
Surge current capacity 0.25 kA
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 2
Frequency 50/60 Hz
Concurrently switching neutral conductor Yes
Rated short-circuit breaking capacity according to IEC 60947-2 10 kA
Connectable conductor cross section solid-core 25 mm²
Connectable conductor cross section multi-wired 1-25 mm²
With interlocking device Yes
Flush-mounted installation No
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 10 kA

Description

FI/LS-Schalter (RCBOs) bieten Personen- und Sachschutz sowie einen Schutz vor elektrisch gezündeten Bränden gemäß DIN VDE 0100-410 und DIN VDE 0100-530. Sie gewährleisten Schutz von Einphasenstromkreisen gegen Überlast und Kurzschlussströme, Schutz bei sinusförmigen Wechselströmen und pulsierenden Strömen mit glattem Gleichfehlerstrom von bis zu 6 mA gegen Erde. Sowie Fehlerschutz (Schutz bei indirektem Berühren), zusätzlichen Schutz und Brandschutz. Einsatzgebiete sind vorwiegend in Gewerbe- und Industrieanwendungen. Das umfangreiche Zubehörsortiment bietet Ihnen alles, was Sie für Ihre Installationsaufgaben benötigen. Die DS202 MA 110V Baureihe hat keine VDE Zulassung und ist speziell für 110 V AC bis 230 V AC Anwendungen einsetzbar. Sie erfüllen die Produktnormen IEC 61009-1, IEC 61009-2-1. Die Zulassungen sind: ABS (USA), DNV (DE), RINA (IT), RMRS (RU). Bemessungsschaltvermögen nach IEC/EN 61009 Icn = 10 kA. RCBO DS202C MA 110V Typ A ist 2-polig geschützt (LS), 2-polig schaltend.