Reflex iC60N Ti24 10 A 2P curve C integrated control MCB
In stock: No
Vendor stock: No
Minimal order quantity: 1
Price (excl. VAT):
228,97 €
This price is valid until 31.12.25
Estimate delivery time at our warehouse (approx.):
By request
Technical Information
Item condition |
New |
Manufacture name |
Reflex iC60N Ti24 10 A 2P curve C integrated control MCB |
Brand |
Schneider Electric
|
Categories |
Breakers
|
Country of origin |
ES |
Harmonized System Code |
8536 2010 00
|
Rated current |
10 A |
Rated voltage |
415 V |
Release characteristic |
C |
Number of poles |
2 |
Rated short-circuit breaking capacity according to EN 60898 |
0 kA |
Rated short-circuit breaking capacity according to IEC 60947-2 |
10 kA |
Packing details
Packing level 1 |
3606480455582 |
Packing level 2 |
3606480455580 |
Other Technical data
Voltage type |
AC |
Built-in depth |
44.5 mm |
Frequency |
50-60 Hz |
Current limiting class |
0 |
Over voltage category |
4 |
Pollution degree |
3 |
Width in number of modular spacings |
4.5 |
Degree of protection (IP) |
IP20 |
Concurrently switching neutral conductor |
No |
Rated switch current auxiliary device |
1 A |
Rated voltage auxiliary device |
230 V |
Control voltage type auxiliary equipment |
AC |
Additional equipment attached at delivery |
Remote drive |
Construction size according to DIN 43880 |
3 |
Downloads
Description
This Acti9 Reflex iC60N is a low voltage integrated control circuit breaker. It is a 2P circuit breaker with protected poles, 10 A rated current and C tripping curve. As circuit breaker, its breaking capacity, according to IEC/EN 60947-2, is 20kA at 220VAC to 240VAC, and 10kA at 380VAC to 415VAC. As a circuit breaker, it protects circuits against short circuit and overload currents, disconnection in the industrial sector. It can control a device remotely by latched and/or impulse-type order according to the 2 operating modes to be chosen by the user. Resetting after a fault is performed manually by the resetting handle. The Ti24 interface allows direct interfacing of the Reflex iC60 with a PLC. It allows to execute remote control, to indicate the state of the control circuit and circuit breaker state information, to connect it to the Acti9 Smartlink thanks to the prefabricated cables. Electrical endurance goes up to 50000 cycles. Mechanical endurance to 50000 cycles. The Ui rated insulation voltage is 500VAC. It can be mounted on DIN rail for modular installation. Its width is 9 modules of 9mm. The product color is white (RAL9003). The dimensions are (W) 81 mm x (H) 84 mm x (D) 77 mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. It becomes IP40 once in modular enclosure with insulation class II.