Register to unlock your exclusive B2B prices and start shopping. Sign up now!
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 1
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 2
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 3
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 4
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 5
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 6
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 7
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 8
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 9
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 10
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A image 11
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 1
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 2
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 3
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 4
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 5
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 6
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 7
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 8
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 9
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 10
mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A thumbnail 11

mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A

In stock: Yes Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
85,88 €
This price is valid until 31.12.25 or while stock lasts
EAN: 4015081184866
MPN: 120656
Package: 1
Box: 30
Estimate delivery time at our warehouse (approx.): 1-4 weeks

Technical Information

Item condition New
Manufacture name mRB6-16/3N/B/03-A RCD/MCB combination, 16 A, 300 mA, MCB trip characteristic: B, 3p+N, RCD trip characteristic: A
Brand EATON
Categories RCBO - (Earth Leakage Breakers)
Country of origin RO
Harmonized System Code 8536 2010 00
Rated current 16 A
Rated voltage 400 V
Release characteristic B
Rated fault current 0.3 A
Leakage current type A
Degree of protection (IP) IP20
Number of protected poles 4
Ambient temperature during operating -25-40 °C
Number of poles (total) 4

Packing details

Packing level 1 4015081184866
Packing level 2 9008790144974

Other Technical data

Voltage type AC
Built-in depth 70 mm
Rated insulation voltage Ui 500 V
Surge current capacity 0.25 kA
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 4
Frequency 50 Hz
Concurrently switching neutral conductor Yes
Rated short-circuit breaking capacity according to IEC 60947-2 0 kA
Connectable conductor cross section solid-core 1-25 mm²
Connectable conductor cross section multi-wired 1-25 mm²
With interlocking device No
Flush-mounted installation No
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 6 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 6 kA

Description

This component provides circuit protection by combining the functions of a Residual Current Device (RCD) and Miniature Circuit Breaker (MCB). The RCD detects earth leakage currents to mitigate risks of electric shock or fire, while the MCB protects against overcurrent conditions such as short circuits or overloads. It is designed for multiphase systems requiring simultaneous protection across live conductors and neutral. **Electrical Characteristics:** Rated current: 16 A. The RCD sensitivity is 300 mA — suitable for equipment-based applications rather than personal protection. MCB trip characteristic: Type B — responds to overloads between 3 and 5 times its rated current, ideal for resistive loads like lighting circuits. **Configuration & Operation:** Poles: 3p+N — covers three active phases plus neutral conductor in one unit. RCD trip characteristic: Type A — detects AC fault currents as well as pulsed DC leakage currents. **Technical Notes / Limitations:** - Not suitable for use with high-inrush inductive loads due to Type B MCB curve; consider other curves if needed. - Designed for operation in systems up to specified phase/neutral configurations; confirm panel compatibility before installation. - Must not exceed permissible load current (16 A) or rated voltage during application—failure may compromise proper tripping behavior. - RCD sensitivity at 300 mA restricts use in residential settings where lower thresholds are often required by local codes/regulations.