Technical Information
Item condition |
New |
Manufacture name |
RCCB with re-closer - RED - 4 poles - 60 A - class A - 300 mA |
Brand |
Schneider Electric
|
Categories |
RCCB - (Residual Current Breakers)
|
Country of origin |
PT |
Voltage type |
AC |
Rated current |
63 A |
Rated voltage |
400 V |
Rated insulation voltage Ui |
500 V |
Number of poles |
4 |
Rated fault current |
300 A |
Leakage current type |
A |
Selective protection |
No |
Short-circuit breaking capacity (Icw) |
10 kA |
Surge current capacity |
0.25 kA |
Short-time delayed tripping |
No |
Frequency |
50 Hz |
Rated impulse withstand voltage Uimp |
4 kV |
Packing details
Packing level 1 |
3303430182696 |
Packing level 2 |
3303430182694 |
Other Technical data
Mounting method |
DIN rail |
Built-in depth |
44 mm |
Pollution degree |
2 |
Width in number of modular spacings |
7 |
Explosion-proof |
No |
Degree of protection (IP) |
IP20 |
Connectable conductor cross section solid-core |
1.5-2.5 mm² |
Connectable conductor cross section multi-wired |
1.5-2.5 mm² |
With interlocking device |
Yes |
Ambient temperature during operating |
-5-40 °C |
Additional equipment possible |
Yes |
Downloads
Description
This Acti9 REDs is a modular residual current circuit breaker (RCCB) with recloser. It is a 4P circuit breaker with 63A In rated current, a sensitivity of 300mA with a A type protection class. This product protects against electrical shock by indirect contact and fire hazards. It disconnects of on-load electric circuits already protected against overloads and short-circuits. It restarts automatically after insulation monitoring of the downstream circuit. It is only used on TT and TN-S earthing grounding systems. The Acti9 REDs and REDtest versions are dedicated to tertiary,industrial and infrastructure applications. This product is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 630A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 4000 cycles. The Ue operational voltage is 400VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 14. The dimensions are (W) 125mm x (H) 98mm x (D) 79.5mm. The weight is 0.68kg. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 40°C. The storage temperature is from -20°C to 60°C.