RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A image 1
RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A image 2
RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A image 3
RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A image 4
RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A thumbnail 1
RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A thumbnail 2
RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A thumbnail 3
RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A thumbnail 4

RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A

Order only
Price (excl. VAT):
81,96 €
This price is valid until 31.12.25
EAN: 4015081079544
MPN: 108328
Package: 1
Box: 30
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name RCD/MCB combination, 16 A, 30 mA, MCB trip characteristic: C, 3p, RCD trip characteristic: A
Brand EATON
Categories RCBO - (Earth Leakage Breakers)
Country of origin* RO
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8536 2010 00
Rated current 16 A
Rated voltage 400 V
Release characteristic C
Rated fault current 0.03 A
Leakage current type A
Degree of protection (IP) IP20
Number of protected poles 3
Ambient temperature during operating -25-40 °C
Number of poles (total) 3

Packing details

Packing level 1 4015081079544
Packing level 2 9007912827412

Other Technical data

Voltage type AC
Built-in depth 70 mm
Rated insulation voltage Ui 500 V
Surge current capacity 0.25 kA
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 4
Frequency 50 Hz
Concurrently switching neutral conductor Yes
Rated short-circuit breaking capacity according to IEC 60947-2 0 kA
Connectable conductor cross section solid-core 1-25 mm²
Connectable conductor cross section multi-wired 1-25 mm²
With interlocking device No
Flush-mounted installation No
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 10 kA

Description

RCD/MCB combination switch, PKPM3, 3-pole, rated current In: 16 A, rated fault current: 0.03 A, rated switching capacity according to IEC/EN 61009: 10 kA, Switchgear for residential and commercial applications