Register to unlock your exclusive B2B prices and start shopping. Sign up now!
QT-FIT5 1X14-35/220-240CW VS20     OSRAM image 1
QT-FIT5 1X14-35/220-240CW VS20     OSRAM image 2
QT-FIT5 1X14-35/220-240CW VS20     OSRAM image 3
QT-FIT5 1X14-35/220-240CW VS20     OSRAM image 4
QT-FIT5 1X14-35/220-240CW VS20     OSRAM thumbnail 1
QT-FIT5 1X14-35/220-240CW VS20     OSRAM thumbnail 2
QT-FIT5 1X14-35/220-240CW VS20     OSRAM thumbnail 3
QT-FIT5 1X14-35/220-240CW VS20     OSRAM thumbnail 4

QT-FIT5 1X14-35/220-240CW VS20 OSRAM

Order only Not Available
Estimate delivery time to our warehouse: By request

Technical Information

Item condition New
Manufacture name QT-FIT5 1X14-35/220-240CW VS20 OSRAM
Brand OSRAM
Country of origin* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8504 1080 00
ETIM EC001497
Width 30 mm
Model Electronic
Suitable for lamp power 14-35 W
Length 280 mm
Nominal voltage 220-240 V
Degree of protection (IP) IP20
Suitable for lamp power (1 lamp) 14-35 W
Suitable for number of lamps 1
Dimming 0-10 V No
Dimming 1-10 V No
Dimming DALI No
Dimming DMX No
Dimming potentiometer (integrated) No
Dimming GPRS No
Dimming LineSwitch No
Dimming manufacturer's proprietary system No
Dimming mains voltage modulation No
Dimming phase cut-off No
Dimming phase cut-on No
Dimming programmable No
Dimming RF No
Dimming Sine Wave Reduction No
Dimming Touch and Dim No
Dimming Zigbee No
Dimming with push-button No
No dim function Yes
Dimming DSI No

Packing details

Packing level 1 4052899927025

Description

CBP_02.00 Product family benefits, all [calc.]: Long lamp life. No adverse effect from frequent on/off switching. Automatic restart after lamp replacement. Perfect lamp start for applications with motion sensors. VDE/VDE EMC certified system. Very high energy efficiency due to cut-off technology. CBP_01.00 Product family features, all [calc.]: Supply voltage: 220…240 V. Line voltage: 198…264 V. Line frequency: 50 Hz | 60 Hz. Lamp start with optimum filament preheating. Energy Efficiency Index EEI: A2. Automatic shutdown of defective lamps and at end of life (EoL T.2). Lamp operation: to EN 60929. Safety: to EN 61347-2-3. CBP_03.00 Areas of applicat, all [calc.]: Open-plan offices, corridors and storage rooms. Public buildings. Strip lighting. Suitable for emergency lighting (DC operation). Suitable for luminaires of protection class I. Modernization of existing systems.