| Item condition | New |
| Manufacture name | Surge Arrester SPCT2-335-3+NPE 3P+NPE 335VAC 20kA |
| Brand | EATON |
| Categories |
Surge Protection Devices (SPD)
|
| Country of origin* | RO |
| * The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager. | |
| Harmonized System Code | 8536 5080 00 |
| ETIM | EC000941 |
| Voltage protection level | 1.6 kV |
| Nominal discharge surge current (8/20) | 20 kA |
| Nominal voltage AC | 335 V |
| Nominal voltage DC | 0 V |
| Voltage protection level L-N | 0 kV |
| Degree of protection (IP) | IP20 |
| Max. PV-voltage | 0 V |
| System configuration DC | No |
| System configuration IT | Yes |
| System configuration TN | Yes |
| System configuration TN-C-S | Yes |
| Packing level 1 | 4015081641116 |
| Packing level 2 | 9008790475009 |
| Mounting method | DIN rail (top hat rail) 35 mm |
| With remote signalling contact | No |
| Number of conductors (without earthing) | 3 |
| Construction size | 4 modular spacing |
| Max. continuous voltage AC | 335 V |
| Category type 2 | Yes |
| Signalling at the device | Optic |
| Max. continuous voltage DC | 0 V |
| Voltage protection level N-PE | 0 kV |
| Integrated backup fuse | No |
| Max. conductor cross section solid (solid, stranded) | 25 mm² |
| Max. conductor cross section flexible (fine-strand) | 35 mm² |
| System configuration TN-C | No |
| System configuration TN-S | Yes |
| System configuration TT | Yes |
| System configuration other | Yes |
| Max. discharge surge current (8/20) | 40 kA |
| Short-circuit breaking capacity (Isccr) | 0 kA |
| Max. overcurrent protection device, parallel connection (fuse) | 0 A |
| Max. overcurrent protection device, series connection (fuse) | 125 A |
| Integrated short-circuit protection | No |
| Integrated short-circuit protection selective to fuse gG | 0 A |
| Leakage-current free | No |
For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear