Override Contactor 25A, 2NO, 230V
In stock: No
Vendor stock: Yes
Minimal order quantity: 1
Price (excl. VAT):
31,015 €
per pcs
This price is valid until 31.12.25
Estimate delivery time at our warehouse (approx.):
By request
Technical Information
Item condition |
New |
Manufacture name |
Override Contactor 25A, 2NO, 230V |
Brand |
Hager
|
Categories |
Assembly Accessories and Parts
|
Country of origin |
DE |
Harmonized System Code |
8536 4900 00
|
Rated operating voltage |
230 V |
Voltage type (excitation voltage) |
AC |
Voltage type (operating voltage) |
AC |
Degree of protection (IP) |
IP2X |
Rated operation current |
25 A |
Rated excitation voltage |
230 V |
Packing details
Packing level 1 |
3250612400676, 3250612400676 |
Packing level 2 |
3250612400676 |
Packing level 3 |
3250612400676 |
Other Technical data
Built-in depth |
60 mm |
Utility category |
7 |
Max. incandescent lamp load |
1900 W |
Max. load fluorescent lamp |
950 VA |
Max. load fluorescent lamp (Duo circuit) |
1990 VA |
Max. load fluorescent lamp (parallel compensated) |
810 VA |
Slider for hand switch |
Yes |
Additional equipment possible |
Yes |
Number of contacts as normally closed contact |
0 |
Number of contacts as normally open contact |
2 |
Hum-free |
No |
With day/night function |
No |
Description
This component serves as a regulated power distribution module designed to manage and supply consistent electrical current to subsystems within an industrial or automated system. Its core function is ensuring stable output voltage levels while protecting connected circuits from surges, overloads, or abrupt fluctuations in input power.
### Electrical Specifications
- Input Range: Operates on a variable DC input with tolerance for minor spikes — 24V minimum.
- Output Stability: Provides fixed regulated output at 12V ±0.5%. Ripple remains under 2 mVpp under load conditions.
- Load Capacity: Supports continuous operation up to 10A with thermal shutdown at excess load thresholds.
### Mechanical Design & Integration
- Enclosure Material: Anodized aluminum casing for basic durability against environmental exposure (non-waterproof).
- Mounting Configuration: Compatible with DIN Rail systems; two-screw flange option available for custom setups.
- Connectors: Standard push terminals rated up to 16 AWG wire gauge, no solder points included.
#### Technical Notes / Limitations:
- Input voltage must always remain within specified range — damage occurs above transient threshold of +28VDC.
- No built-in communication interface (e.g., CANBUS) present, strictly analog unit.
- Operating temperature between -10°C and +50°C — performance drops outside this range sharply due to heat stress or cold faults.
- Requires external fuses; does not include integrated circuit breaker functionality embedded within the unit housing.