Register to unlock your exclusive B2B prices and start shopping. Sign up now!
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 1
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 2
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 3
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 4
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 5
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 6
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 7
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 8
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 9
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 10
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity image 11
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 1
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 2
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 3
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 4
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 5
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 6
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 7
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 8
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 9
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 10
NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity thumbnail 11

NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
3 659,44 €
This price is valid until 31.12.25
EAN: 4015081928279
MPN: 192276
Package: 1
Estimate delivery time at our warehouse (approx.): 1-4 weeks

Technical Information

Item condition New
Manufacture name NZMH3-PX630-TAZ-AVE NZM3 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 3p, earth-fault protection, ARMS and zone selectivity
Brand EATON
Categories Power Circuit Breakers
Country of origin RO
Harmonized System Code 8536 2090 00
Rated permanent current Iu 630 A
Number of poles 3
Rated voltage 690 V
Degree of protection (IP) IP20
With switched-off indicator No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 150 kA
Integrated earth fault protection Yes
Device construction Built-in device slide-in technique (withdrawable)

Packing details

Packing level 1 4015081928279

Other Technical data

Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
With integrated under voltage release No
Overload release current setting 252-630 A
Number of auxiliary contacts as change-over contact 0
Position of connection for main current circuit Connection at separate chassis part
Motor drive integrated No
Type of electrical connection of main circuit Other
Type of control element Rocker lever
Adjustment range short-term delayed short-circuit release 1.5-7 A
Adjustment range undelayed short-circuit release 1260-10080 A
Suitable for DIN rail (top hat rail) mounting No
Motor drive optional Yes
DIN rail (top hat rail) mounting optional No
Complete device with protection unit Yes

Description

The xEffect NZM...-PX...-TAZ circuit breaker range with power expert release (PXR) electronic triggering system covers use cases for full range protection including earth fault protection with only four compact sizes and is suitable for the IEC market. The integrated energy measuring function supplies currents, voltages and active energy (kWh) with accuracy class 1 according to IEC 61557-12. Maintenance mde ARMS and zone selectivity for extended protection included. Test function and settings via micro USB port directly on the switch . Modular function groups always make mounting flexible and may be supplemented by the comprehensive range of accessories. R.m.s. value measurement and thermal memory.

Similar items

Accessories

Suitable for

Similar items
4015082601706 4015082601546 4015082601768 4015082601829 4015082601935 4015082667115 4015082714611 4015082856021 4015082855574 4015082856014
Accessories
4015082601706 4015082601546 4015082601768 4015082601829 4015082601935 4015082667115 4015082714611 4015082856021 4015082855574 4015082856014
Suitable for
4015082601546 4015082601768 4015082601829 4015082601935 4015082667115 4015082714611 4015082856021 4015082855574 4015082856014 4015081004980