Off-delay timer, 1 NO contact 10A
In stock: No
Vendor stock: No
Minimal order quantity: 1
Price (excl. VAT):
36,90 €
This price is valid until 31.12.25
Estimate delivery time at our warehouse (approx.):
2-4 weeks
Technical Information
Item condition |
New |
Manufacture name |
Off-delay timer, 1 NO contact 10A |
Brand |
ELTAKO
|
Categories |
Push Buttons and Control
|
Country of origin |
CN |
Harmonized System Code |
8536 5080 00
|
Mounting method |
Flush mounted (plaster) |
Function |
Operating and release delay |
Width in number of modular spacings |
0 |
Number of changeover switches |
0 |
Voltage type of supply voltage |
AC |
Supply voltage |
250 V |
1st interval unit |
Minutes/hours |
2nd interval unit |
Seconds/minutes |
1st interval |
0-12 |
2nd interval |
1-12 |
Nominal switching current at 250 V AC |
10 A |
Switch capacity incandescent lamps |
2000 W |
Number of contacts as normally closed contact |
0 |
Number of contacts as normally open contact |
1 |
Packing details
Packing level 1 |
4010312603048, 4010312603048 |
Packing level 2 |
4010312603048 |
Packing level 3 |
4010312603048 |
Other Technical data
Built-in height |
18 mm |
Control voltage 1 |
8-230 V |
Type of control voltage 1 |
AC/DC |
Frequency control voltage 1 |
50 Hz |
Switch capacity fluorescent lamp DUO |
1000 VA |
Switch capacity fluorescent lamp parallel |
500 VA |
Downloads
Description
1 NO contact not potential free 10A/250V AC. Standby loss 0.7 watt only. Built-in device for installation. 45mm long, 45mm wide, 18mm deep. Zero passage switching to protect contacts and consumers. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. 8 to 230V UC universal control voltage, electrically isolated from the 230V supply voltage and switching voltage. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. The top rotary switch varies the off-delay time from 1 to 12 minutes. Operating delay settable from 0 to 12 minutes with the lower rotary switch. Function: When the control contact (light switch) is closed the operating delay AV starts (if not set 0 minutes), on time-out the fan is switched on. The set release delay RV (delay time) starts when the control contact opens and if a set operating delay has elapsed. The fan switches off on time-out. This off-delay timer can be controlled by all dimmer switches EUD12 and EUD61 even in the minimum dimming position.