Analogue settable multifunction time relay, 1 NO contact 10A
In stock: No
Vendor stock: No
Minimal order quantity: 1
Price (excl. VAT):
36,22 €
This price is valid until 24.12.25
Estimate delivery time at our warehouse (approx.):
4-6 weeks
Technical Information
Item condition |
New |
Manufacture name |
Analogue settable multifunction time relay, 1 NO contact 10A |
Brand |
ELTAKO
|
Categories |
Push Buttons and Control
|
Country of origin |
CN |
Harmonized System Code |
8536 4900 00
|
Mounting method |
Surface mounted (plaster) |
Function |
Multi function |
Type of excitation |
Analogue with multi function |
Width in number of modular spacings |
0 |
Number of changeover switches |
0 |
Voltage type of supply voltage |
AC/DC |
Supply voltage |
8-230 V |
1st interval unit |
Minutes/hours |
1st interval |
1 |
Switch capacity incandescent lamps |
2000 W |
Number of contacts as normally closed contact |
0 |
Number of contacts as normally open contact |
1 |
Packing details
Packing level 1 |
4010312603055, 4010312603055 |
Packing level 2 |
4010312603055 |
Packing level 3 |
4010312603055 |
Other Technical data
Built-in height |
18 mm |
Control voltage 1 |
8-230 V |
Type of control voltage 1 |
AC/DC |
Frequency control voltage 1 |
50 Hz |
Switch capacity fluorescent lamp DUO |
1000 VA |
Switch capacity fluorescent lamp parallel |
500 VA |
Downloads
Description
1 NO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 2000W*. Standby loss 0.02–0.4 watt only. Built-in device for installation. 45mm long, 45mm wide, 18mm deep. With the patented Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 1(L) for this. This gives an additional standby consumption of only 0.1 watt. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. Universal control voltage input 8 to 230V UC. Supply voltage is same as the control voltage. Time settings between 0.5 seconds and 1 hour. Functions F: RV = off delay. AV = operating delay. TI = clock generator starting with impulse. IA = impulse-controlled operating delay. EW = fleeting NO contact. AW = fleeting NC contact. * The maximum load can be used from a delay time or clock cycle of 5 minutes. The maximum load is reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.