Item condition |
New |
Manufacture name |
MC GC1300 pro22 Cat.7A S/FTP 4P LSHF-FR 3280 ft, class Dca s2 d2 a1 |
Brand |
METZ CONNECT
|
Categories |
Ethernet cable (network)
|
Country of origin |
SI |
Harmonized System Code |
8544 4920 00
|
UV resistant |
No |
Material core insulation |
Other |
Core identification |
Colour |
Cable type |
S/FTP |
Weight |
66.5 kg/km |
Drain wire |
No |
Stranding element |
Pairs |
Colour outer sheath |
Blue |
Category |
7A (IEC) |
Diameter conductor |
0.62 mm |
Conductor material |
Copper |
Screen over stranding element |
Foil |
Screen over stranding |
Braiding |
Material outer sheath |
Other |
Conductor category |
Class 1 = solid |
Armouring/reinforcement |
None |
Permitted cable outer temperature during assembling/handling |
0-50 °C |
Permitted cable outer temperature after assembling without vibration |
-20-60 °C |
Number of stranding elements |
4 |
Protective sheath |
None |
Number of cores |
8 |
Suitable for underground installation |
No |
Halogen free according to IEC 60754-2 |
Yes |
Low smoke according to IEC 61034-2 |
No |
Stranding |
Other |
Outer diameter approx. |
8.1 mm |
With rodent protection |
No |
NVP value |
79 % |
Oil resistant according to IEC 60811-404 |
No |
Conductor surface |
Bare |
Longitudinal water blocking cable |
No |
Radial water blocking cable |
No |
Reaction-to-fire according to EN 13501-6: Class |
Dca |
Reaction-to-fire according to EN 13501-6: Smoke production |
s2 |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles |
d2 |
Reaction-to-fire according to EN 13501-6: Acidity |
a1 |
AWG size |
22 |
Min. permitted bending radius, moving application/free movement |
60 mm |
Min. permitted bending radius, stationary application/permanent installation |
30 mm |
Specification core insulation |
Polyethylene (PE) |
Specification material outer sheath |
Other |
Cable geometry |
Round |
Core identification according to HD 308 S2 |
No |
Suitable as telephone cable |
No |
Suitable as computer data cable |
No |
Suitable as signalling cable |
No |
Certified for shipboard application |
No |
Flame retardant according to IEC 60332-1-2 |
No |
Flame retardant according to IEC 60332-3-21 (Cat A F/R) |
No |
Flame retardant according to IEC 60332-3-22 (Cat A) |
No |
Flame retardant according to IEC 60332-3-23 (Cat B) |
No |
Flame retardant according to IEC 60332-3-24 (Cat C) |
Yes |
Flame retardant according to IEC 60332-3-25 (Cat D) |
No |
Halogen free according to IEC 60754-1 |
No |
Halogen free according to IEC 60754-3 |
No |
Circuit integrity according to IEC 60331-23 |
No |
Compatible with Grade2TV according to XP-C 90-483 |
No |
Compatible with Grade3TV according to XP-C 90-483 |
No |