T5B-3-15284/EA/SVB Main switch, T5B, 63 A, flush mounting, 3 contact unit(s), 3 pole + N, 1 N/O, 1 N/C, Emergency switching off function, With red rotary handle and yell
In stock: No
Vendor stock: No
Minimal order quantity: 1
Price (excl. VAT):
116,46 €
This price is valid until 24.12.25
Estimate delivery time at our warehouse (approx.):
4-6 weeks
Technical Information
Item condition |
New |
Manufacture name |
T5B-3-15284/EA/SVB Main switch, T5B, 63 A, flush mounting, 3 contact unit(s), 3 pole + N, 1 N/O, 1 N/C, Emergency switching off function, With red rotary handle and yell |
Brand |
EATON
|
Categories |
Switch Disconnectors
|
Country of origin |
GB |
Harmonized System Code |
8536 5080 00
|
Rated permanent current Iu |
63 A |
Number of poles |
4 |
Rated operating voltage |
690 V |
Degree of protection (IP), front side |
IP65 |
Version as main switch |
Yes |
Version as safety switch |
No |
Version as maintenance-/service switch |
Yes |
Rated short-time withstand current lcw |
1.3 kA |
Packing details
Packing level 1 |
4015080924883 |
Other Technical data
Width |
88 |
Height |
88 |
Depth |
156 |
Rated operation power at AC-3, 400 V |
22 kW |
Number of auxiliary contacts as normally open contact |
2 |
Number of auxiliary contacts as normally closed contact |
1 |
Conditioned rated short-circuit current Iq |
2 kA |
Number of auxiliary contacts as change-over contact |
0 |
Number of switches |
1 |
Interlockable |
Yes |
Motor drive integrated |
No |
Type of electrical connection of main circuit |
Screw connection |
Version as emergency stop installation |
Yes |
Type of control element |
Door coupling rotary drive |
Rated operation power at AC-23, 400 V |
30 kW |
Colour control element |
Red |
Suitable for floor mounting |
No |
Suitable for front mounting 4-hole |
Yes |
Suitable for front mounting centre |
No |
Suitable for distribution board installation |
No |
Suitable for intermediate mounting |
No |
Max. rated operation voltage Ue AC |
690 V |
Motor drive optional |
No |
Voltage release optional |
No |
Device construction |
Built-in device fixed built-in technique |
Rated permanent current at AC-21, 400 V |
63 A |
Switching power at 400 V |
30 kW |
Version as reversing switch |
No |
Rated permanent current at AC-23, 400 V |
63 A |
Degree of protection (NEMA) |
12 |
With pre-assembled cabling |
No |
Description
Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: T5B, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, 3 pole + N, Degree of Protection: Front IP65, Design: flush mounting, Switching angle: 90 °, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 30 kW, Rated uninterrupted current: Iu = 63 A, 3 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3