Technical Information
                
                    
                        
                            | Item condition | 
                            New | 
                        
                        
                            | Manufacture name | 
                            T3-2-1/EA/SVB Main switch, T3, 32 A, flush mounting, 2 contact unit(s), 3 pole, Emergency switching off function, With red rotary handle and yellow locking ring | 
                        
                                                    
                                | Brand | 
                                
                                    EATON
                                 | 
                            
                                                                            
                                | Categories | 
                                
                                                                            
                                        Switch Disconnectors
                                        
                                         
                                                                     | 
                            
                                                                            
                                | Country of origin | 
                                GB | 
                            
                                                                            
                                | Harmonized System Code | 
                                
                                    
                                        8536 5080 00
                                    
                                 | 
                            
                                                                                                                                    
                                    | Rated permanent current Iu | 
                                    32 A | 
                                
                                                            
                                    | Number of poles | 
                                    3  | 
                                
                                                            
                                    | Rated operating voltage | 
                                    690 V | 
                                
                                                            
                                    | Degree of protection (IP), front side | 
                                    IP65  | 
                                
                                                            
                                    | Version as main switch | 
                                    Yes  | 
                                
                                                            
                                    | Version as safety switch | 
                                    No  | 
                                
                                                            
                                    | Version as maintenance-/service switch | 
                                    Yes  | 
                                
                                                            
                                    | Rated short-time withstand current lcw | 
                                    0.65 kA | 
                                
                                                                        
                 
                                    Packing details
                    
                        
                                                            
                                    | Packing level 1 | 
                                    4015080286127 | 
                                
                                                    
                     
                
                                    Other Technical data
                    
                                                    
                                                                    
                                        | Width | 
                                        65  | 
                                    
                                                                    
                                        | Height | 
                                        74  | 
                                    
                                                                    
                                        | Depth | 
                                        116  | 
                                    
                                                                    
                                        | Rated operation power at AC-3, 400 V | 
                                        11 kW | 
                                    
                                                                    
                                        | Number of auxiliary contacts as normally open contact | 
                                        0  | 
                                    
                                                                    
                                        | Number of auxiliary contacts as normally closed contact | 
                                        0  | 
                                    
                                                                    
                                        | Conditioned rated short-circuit current Iq | 
                                        1 kA | 
                                    
                                                                    
                                        | Number of auxiliary contacts as change-over contact | 
                                        0  | 
                                    
                                                                    
                                        | Number of switches | 
                                        1  | 
                                    
                                                                    
                                        | Interlockable | 
                                        Yes  | 
                                    
                                                                    
                                        | Motor drive integrated | 
                                        No  | 
                                    
                                                                    
                                        | Type of electrical connection of main circuit | 
                                        Screw connection  | 
                                    
                                                                    
                                        | Version as emergency stop installation | 
                                        Yes  | 
                                    
                                                                    
                                        | Type of control element | 
                                        Door coupling rotary drive  | 
                                    
                                                                    
                                        | Rated operation power at AC-23, 400 V | 
                                        15 kW | 
                                    
                                                                    
                                        | Colour control element | 
                                        Red  | 
                                    
                                                                    
                                        | Suitable for floor mounting | 
                                        No  | 
                                    
                                                                    
                                        | Suitable for front mounting 4-hole | 
                                        No  | 
                                    
                                                                    
                                        | Suitable for front mounting centre | 
                                        Yes  | 
                                    
                                                                    
                                        | Suitable for distribution board installation | 
                                        No  | 
                                    
                                                                    
                                        | Suitable for intermediate mounting | 
                                        No  | 
                                    
                                                                    
                                        | Max. rated operation voltage Ue AC | 
                                        690 V | 
                                    
                                                                    
                                        | Motor drive optional | 
                                        No  | 
                                    
                                                                    
                                        | Voltage release optional | 
                                        No  | 
                                    
                                                                    
                                        | Device construction | 
                                        Built-in device fixed built-in technique  | 
                                    
                                                                    
                                        | Rated permanent current at AC-21, 400 V | 
                                        32 A | 
                                    
                                                                    
                                        | Switching power at 400 V | 
                                        15 kW | 
                                    
                                                                    
                                        | Version as reversing switch | 
                                        No  | 
                                    
                                                                    
                                        | Rated permanent current at AC-23, 400 V | 
                                        32 A | 
                                    
                                                                    
                                        | Degree of protection (NEMA) | 
                                        12  | 
                                    
                                                                    
                                        | With pre-assembled cabling | 
                                        No  | 
                                    
                                                            
                                             
                
                
                
                
                
                                    Description
                    
                        Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: T3, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, 3 pole, Degree of Protection: Front IP65, Design: flush mounting, Switching angle: 90 °, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 15 kW, Rated uninterrupted current: Iu = 32 A, 2 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3