Technical Information
                
                    
                        
                            | Item condition | New | 
                        
                            | Manufacture name | T0-2-8324/V/SVB Main switch, T0, 20 A, rear mounting, 2 contact unit(s), 4 pole, Emergency switching off function, With red rotary handle and yellow locking ring | 
                                                    
                                | Brand | EATON | 
                                                                            
                                | Categories | Switch Disconnectors 
 | 
                                                                            
                                | Country of origin | GB | 
                                                                            
                                | Harmonized System Code | 8536 5080 00 | 
                                                                                                                                    
                                    | Rated permanent current Iu | 20 A | 
                                                            
                                    | Number of poles | 4 | 
                                                            
                                    | Rated operating voltage | 690 V | 
                                                            
                                    | Degree of protection (IP), front side | IP65 | 
                                                            
                                    | Version as main switch | Yes | 
                                                            
                                    | Version as safety switch | No | 
                                                            
                                    | Version as maintenance-/service switch | Yes | 
                                                            
                                    | Rated short-time withstand current lcw | 0.32 kA | 
                                                                        
                 
                                    Packing details
                    
                        
                                                            
                                    | Packing level 1 | 4015080988410 | 
                                                    
                     
                
                                    Other Technical data
                    
                                                    
                                                                    
                                        | Width | 65 | 
                                                                    
                                        | Height | 74 | 
                                                                    
                                        | Depth | 128 | 
                                                                    
                                        | Rated operation power at AC-3, 400 V | 5.5 kW | 
                                                                    
                                        | Number of auxiliary contacts as normally open contact | 0 | 
                                                                    
                                        | Number of auxiliary contacts as normally closed contact | 0 | 
                                                                    
                                        | Conditioned rated short-circuit current Iq | 6 kA | 
                                                                    
                                        | Number of auxiliary contacts as change-over contact | 0 | 
                                                                    
                                        | Number of switches | 1 | 
                                                                    
                                        | Interlockable | Yes | 
                                                                    
                                        | Motor drive integrated | No | 
                                                                    
                                        | Type of electrical connection of main circuit | Screw connection | 
                                                                    
                                        | Version as emergency stop installation | Yes | 
                                                                    
                                        | Type of control element | Door coupling rotary drive | 
                                                                    
                                        | Rated operation power at AC-23, 400 V | 5.5 kW | 
                                                                    
                                        | Colour control element | Red | 
                                                                    
                                        | Suitable for floor mounting | Yes | 
                                                                    
                                        | Suitable for front mounting 4-hole | No | 
                                                                    
                                        | Suitable for front mounting centre | No | 
                                                                    
                                        | Suitable for distribution board installation | No | 
                                                                    
                                        | Suitable for intermediate mounting | Yes | 
                                                                    
                                        | Max. rated operation voltage Ue AC | 690 V | 
                                                                    
                                        | Motor drive optional | No | 
                                                                    
                                        | Voltage release optional | No | 
                                                                    
                                        | Device construction | Built-in device fixed built-in technique | 
                                                                    
                                        | Rated permanent current at AC-21, 400 V | 20 A | 
                                                                    
                                        | Switching power at 400 V | 5.5 kW | 
                                                                    
                                        | Version as reversing switch | No | 
                                                                    
                                        | Rated permanent current at AC-23, 400 V | 13.3 A | 
                                                                    
                                        | Degree of protection (NEMA) | 12 | 
                                                                    
                                        | With pre-assembled cabling | No | 
                                                            
                                             
                
                
                
                
                
                                    Description
                    
                        Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: T0, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, 4 pole, Degree of Protection: Front IP65, Design: rear mounting, Switching angle: 90 °, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 5.5 kW, Rated uninterrupted current: Iu = 20 A, 2 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3