Undervoltage release for NZM2/3, configurable relays, 2NO, 208-240AC, Push-in terminals
Yra sandėlyje: Ne
Pardavėjo atsargos: Ne
Minimalus užsakymo kiekis: 1
Ši kaina galioja iki 24.12.25
Numatomas pristatymo laikas į mūsų sandėlį (apytiksliai):
4-6 weeks
Technical Information
Prekės būklė |
Nauja |
Gamintojo pavadinimas |
NZM2/3-XU2A208-240AC Undervoltage release for NZM2/3, configurable relays, 2NO, 208-240AC, Push-in terminals |
Prekės ženklas |
EATON
|
Kategorijos |
Trip & Release Units
|
Kilmės šalis |
RO |
Suderintos sistemos kodas |
8538 9099 00
|
Elektrinės jungties tipas |
Spyruoklinio spaustuvo jungtis |
Nominali kontrolės maitinimo įtampa, kai AC 50 Hz |
208-240 V |
Nominali kontrolės maitinimo įtampa, kai AC 60 Hz |
208-240 V |
DC nominali kontrolės maitinimo įtampa |
0 V |
Aktyvacijos įtampos tipas |
Kintamoji srovė |
Pakavimo informacija
Pakavimo lygis 1 |
4015081877225 |
Kiti techniniai duomenys
Uždelstas |
No |
Tinka jungiklio atjungėjui |
Yes |
Tinka perkrovos relei |
No |
Tinka variklio saugos jungikliui |
Yes |
Tinka maitinimo grandinės atjungikliui |
No |
Įprastai uždarytų kontaktų skaičius |
0 |
Įprastai atvirų kontaktų skaičius |
2 |
Perjungimo kontaktų skaičius |
0 |
Aprašymas
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Undervoltage releases with two relays. Non-delayed disconnection of circuit-breaker NZM when control voltage drops below 35 - 70 % Us. For use with emergency switching off devices in conjunction with emergency switching off buttom. For signalizing commands or different states of the circuit-breaker. Two relays per unit. Actuation reason can be configured in the trip unit . Configuration via communication or circuit breaker display or front USB connection and Eaton Power Xpert Protection Manager. When the undervoltage release is de-energized, accidental contact with the main contacts of the circuit-breaker dureing attempts to switch on is reliably prevented. Only suitable for use in conjunction with circuit-breakers with electronic releases. Undervoltage release relais modules cannot be installed simultaneously with early-make contact NZM…-XHIV, or untervoltage release NZM…-XU…, or shunt release NZM…-XA… Relay coil actuated by trip unit. Relay contact for control wiring. Control wiring to push-in terminals . Cannot be used with PXR10 NZM-AE electronic release.