Registruokitės, kad atrakintumėte savo išskirtines B2B kainas ir pradėtumėte apsipirkinėti. Užsiregistruokite dabar!
REG emergency power supply, light grey image 1
REG emergency power supply, light grey image 2
REG emergency power supply, light grey image 3
REG emergency power supply, light grey image 4
REG emergency power supply, light grey thumbnail 1
REG emergency power supply, light grey thumbnail 2
REG emergency power supply, light grey thumbnail 3
REG emergency power supply, light grey thumbnail 4

REG emergency power supply, light grey

Tik užsakymas
Kaina (be PVM):
92,90 €
Ši kaina galioja iki 28.02.26
EAN: 3606485100265
MPN: MTN683901
Pakuotė: 1
Dėžė: 10
Numatomas pristatymo laikas į mūsų sandėlį (apytiksliai): 4-6 weeks

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas REG emergency power supply, light grey
Prekės ženklas Schneider Electric
Kategorijos Bus System Devices (KNX/Modbus)
Kilmės šalis* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Montavimo metodas DRA
Maks. išeigos srovė 640 mA
Antrinė įtampa 230 V
EIB / KNX magistralės sistema Yes

Pakavimo informacija

Pakavimo lygis 1 3606485100265
Pakavimo lygis 2 3606485100263

Kiti techniniai duomenys

Integruotų blokavimo induktorių skaičius 0
Perduodamų linijų skaičius 0
Magistralės sistemos radijo dažnis No
„Powernet“ magistralės sistema No
Buferinė magistralės įtampa No
Modulinių tarpų skaičius plotyje 4
Kitos maršrutinės sistemos Nėra
LON magistralinė sistema No
Su LED rodmeniu Yes
KNX radijo magistralės sistema No

Atsisiuntimai

Aprašymas

REG emergency power supply. To buffer the bus voltage. If a complete mains failure occurs, an external lead gel battery with a voltage of DC 12 V (SELV) can be connected to the REG power supply for buffering. The lead gel battery is recharged or maintained in its charged state by integrated charging electronics. A binary input can be connected in order to register the operational statuses (mains voltage, error warning, battery operation). For installation on DIN rails TH35 according to EN 60715. A data rail is not necessary. Nominal voltage: AC 110-230 V ±10%. Operating voltage: min. AC 92 V - max. AC 253 V. Mains frequency: 50-60 Hz ±10%. Output to power supply: Output voltage: DC 30 V ±2 V. Output current: without battery with mains supply max. 300 mA, with battery without mains supply max. 640 mA. Buffer time with lead gel battery 7,2 Ah: MTN683890: approx. 0.5 h. MTN683832: approx. 1 h. Buffer time with lead gel battery 18 Ah: MTN683890: approx. 1.25 h. MTN683832: approx. 2.5 h. Short-circuit current: 1.5 A. Charging current: max. 1 A. Connections: plug-in screw terminal for main connector, operating state (4-pin, 3 floating contacts) and emergency power supply. Plug-in terminal for battery connection (two 1 mm pins). Device width: 4 modules, approx. 72 mm. Contents: With connecting terminal and cable cover. Colour: light grey.