Registruokitės, kad atrakintumėte savo išskirtines B2B kainas ir pradėtumėte apsipirkinėti. Užsiregistruokite dabar!
NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right image 1
NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right image 2
NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right image 3
NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right image 4
NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right thumbnail 1
NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right thumbnail 2
NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right thumbnail 3
NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right thumbnail 4

Earth-fault release, 0.03-3A, 3p, right

Tik užsakymas
Kaina (be PVM):
277,38 €
Ši kaina galioja iki 24.12.25
EAN: 4015081044153
MPN: 104605
Pakuotė: 1
Numatomas pristatymo laikas į mūsų sandėlį (apytiksliai): 4-6 weeks

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas NZM1-XFIR Earth-fault release, 0.03-3A, 3p, right
Prekės ženklas EATON
Kategorijos Trip & Release Units
Kilmės šalis* CZ
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Suderintos sistemos kodas 8538 9099 00
Nominali gedimo srovė nuo / iki 0.03-3 A
Nominali kontrolės maitinimo įtampa, kai AC 50 Hz 200-415 V
Nominali kontrolės maitinimo įtampa, kai AC 60 Hz 200-415 V
DC nominali kontrolės maitinimo įtampa 0 V
Maks. nominali operacinė įtampa Ue 415 V

Pakavimo informacija

Pakavimo lygis 1 4015081044153

Kiti techniniai duomenys

Reguliuojama delsa Yes
Maks. aktyvavimo delsos laikas 30 ms

Aprašymas

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: approved according to IEC/EN 60947-2 not UL/CSA approved. Suitable for use in three- and single-phase systems. Pulse current sensitive according to core-balance principle. For 3 and 4 pole NZM1(-4) circuit-breakers and switch-disconnectors N1(-4).mains voltage independent Ue = 200 .. 415 V 50/60 Hz. At I △n = 0.03 A: delay time t v always fixed setting to 10 ms. Warning message > 30 % I △n by yellow LED . Trip indication max. 2 auxiliary contacts (HIAFI) can be fitted by user: N/O = M22-K01, N/C = M22-K10 are reset via the reset button. If the trip-indicating auxiliary contact in the fault current block is used, the N/C contacts operates as a N/O contact and the N/C contact operates as an N/O contact. Double contact not permissible. Not in combination with insulated enclosure or main switch assembly kit for side panel mounting with mounting bracket. NZM1-XFI...R can not be used in combination with lower cover NZM1-XUSA.NZM1-XFI…U not in combination with shunt or undervoltage release, early-make auxiliary contacts . Rated ultimate short-circuit breaking capacity is determined by fitted NZM1, NS1. When using a switch-disconnector N1, by the back-up fuse to be used. See technical data. Can be used for: NZM1, N(S)1