Register to unlock your exclusive B2B prices and start shopping. Sign up now!
VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2 image 1
VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2 image 2
VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2 image 3
VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2 thumbnail 1
VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2 thumbnail 2
VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2 thumbnail 3

VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2

Order only Minimal order quantity: 40
Price (excl. VAT):
123,01 € per pcs
This price is valid until 31.12.25
Subtotal: 4 920,40 € MOQ: 40
EAN: 4055626949239
MPN: 1099593
Box: 1
Estimate delivery time at our warehouse (approx.): 4-6 weeks

Technical Information

Item condition New
Manufacture name VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 - Lightning/surge arrester type 1/2
Brand Phoenix Contact
Categories Surge Protection Devices (SPD)
Country of origin* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Harmonized System Code 8536 3030 00
Voltage protection level 3.5 kV
Nominal discharge surge current (8/20) 15 kA
Nominal voltage AC 0 V
Nominal voltage DC 0 V
Voltage protection level L-N 3.5 kV
Degree of protection (IP) Other
Max. PV-voltage 0 V

Packing details

Packing level 1 4055626949239, 4055626949239

Other Technical data

Mounting method Other
With remote signalling contact Yes
Number of conductors (without earthing) 0
Construction size 3 modular spacing
Max. continuous voltage AC 0 V
Category type 2 No
Signalling at the device Optic
Max. continuous voltage DC 1050 V
Voltage protection level N-PE 3.5 kV
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 0 mm²
Max. discharge surge current (8/20) 0 kA
Short-circuit breaking capacity (Isccr) 0 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Integrated short-circuit protection selective to fuse gG 0 A

Description

Lightning current arrester / surge protective device for 2-pos. isolated and grounded 1,000 V DC PV voltage systems, for DIN rail mounting, 3-pos. base element with remote indication contact, three pluggable temperature-monitored protective elements, status message at each plug.